Maintenance, Test & Measurement, Calibration


New toxic gas tools

March 2008 Maintenance, Test & Measurement, Calibration

RAE Systems, a provider of rapidly deployable sensor networks that enable customers to identify safety and security threats in realtime, has introduced the ToxiRAE 3 family of single-gas monitors and the AutoRAE Lite bump test and calibration station. ToxiRAE 3 features a stainless-steel front cover to withstand harsh environments and is currently available in three models: hydrogen sulphide and high- and low-range carbon monoxide. These toxic-gas monitors carry US, Canada, EU and global IECEX safety certificates for use in hazardous environments in the global oil, gas production, refining, steel and first responder markets.

"The ToxiRAE 3 joins RAE System's other gas monitoring products in providing real results in realtime by offering the fastest instrument response time in a single gas monitor," said Lisa Mork, director of marketing for RAE Systems. "The ToxiRAE 3 also has a rugged stainless-steel cover for use in dirty industrial environments."

"The AutoRAE Lite bump test and calibration station work together with the ToxiRAE 3 to quickly and easily check for proper alarm levels and to calibrate as required," said Thomas Negre, director of instrumentation products for RAE Systems. "The AutoRAE Lite will also be a favourite product for large corporate users who want to keep records of all calibration and alarm data."

All three monitors have end-user configurable operating-modes as either operating days remaining or gas concentration display mode. The detectors all feature multiphase alarms (vibration, 95 dB siren and flashing light) for short term exposure limit (STEL), time weighted average (TWA) exposure and high/low alarms. The unit is designed to be used continuously in environments with temperatures ranging from -20 to +60°C and has an IP67 waterproof rating.

The hydrogen sulphide monitor has a measurement range of 0,1 to 100 parts per million (ppm). The carbon monoxide units are available in measurement ranges of either 0 to 500 or 0 to 1999 ppm. All three products can store up to 10 alarm events for later reference. The US/Canada intrinsic safety certification covers operating zones C1D1 Groups A, B, C, D and T4. The EU certification is for ATEX II 1G EEX ia T4.

The bump test and calibration station is small enough to be installed where necessary and provides a fast, 12-second bump test or a full calibration in two minutes.





Share this article:
Share via emailShare via LinkedInPrint this page

Further reading:

Collect data three times faster
SKF South Africa Maintenance, Test & Measurement, Calibration
SKF has extended its renowned Microlog Analyzer family of data collection devices with the addition of the Microlog Analyzer dBX. Currently SKF’s most powerful diagnostic tool, this cutting-edge device redefines diagnostic capabilities, enabling users to take measurements three times faster than its predecessor.

Read more...
The criticality of maintenance in the water and wastewater segment
Schneider Electric South Africa Maintenance, Test & Measurement, Calibration
In a time of water shedding, climate change and ageing infrastructure, the importance of maintenance and support in the water and wastewater segment cannot be overstated.

Read more...
How dry ice blasting is revolutionising the mining industry
Maintenance, Test & Measurement, Calibration
Dry ice blasting has emerged as a game-changing technology for the mining industry, offering a range of advantages that are reshaping traditional cleaning methods.

Read more...
Quality test tools save costs at pulp and paper mill
Comtest Editor's Choice Maintenance, Test & Measurement, Calibration
A case study on how preventive maintenance and a few good test tools avoided unnecessary motor replacements at a pulp and paper company.

Read more...
The logical solution to oil and gas industry corrosion
Maintenance, Test & Measurement, Calibration
The consequences of corrosion in the oil and gas industry can be astronomical. The simple culprit is metal reacting with oxygen and moisture, degrading it back to its natural state.

Read more...
Lube tip: foaming is affected by oil level
Wearcheck Maintenance, Test & Measurement, Calibration
In a circulating system, it is crucial to check the oil level before introducing anti-foam agents to address a foaming problem.

Read more...
Microfine filtration boosts fuel quality and reduces equipment failure
Maintenance, Test & Measurement, Calibration
The path to contamination-free fuels relies on a combined effort from refiners to transporters, storage depots, handlers and end users. Prior to use, fuels can be polished with multi-pass microfine filtration systems such as those exclusively manufactured by ISO-Reliability Partners.

Read more...
Supporting capital investment in machinery
Maintenance, Test & Measurement, Calibration
Industrial and mining operations are under increased financial pressure in the current economic and social climate in South Africa. This means that when businesses make capital investments in new equipment, they need to be sure that the machinery will function optimally for as long as possible.

Read more...
High-accuracy automated pressure calibrator
Maintenance, Test & Measurement, Calibration
The Additel 762 Automated Pressure Calibrator is unlike any other pressure calibrator on the market. This revolutionary product is a complete turnkey solution for automation of pressure calibration work ...

Read more...
Handheld pressure calibrator
Maintenance, Test & Measurement, Calibration
The 273Ex from Additel is an intrinsically safe handheld multifunctional pressure calibrator with an intuitive colour touchscreen interface. The unit features built-in quick test tasks and optional HART ...

Read more...