Maintenance, Test & Measurement, Calibration


Tech tips: Comtest Distribution - Using thermal imaging for MCC maintenance

August 2007 Maintenance, Test & Measurement, Calibration

Thermal imaging can be used to evaluate the operating condition of the components within motor control centres (MCCs) by comparing the relative temperatures of components under load.

Thermal imagers can indicate the operating condition of the components within MCCs by comparing their relative temperatures under load.

Key components to be monitored include bus bars, controllers, starters, contactors, relays, fuses, breakers, disconnects, feeders and transformers.

Caution

Only authorised and qualified personnel using the appropriate personal protective equipment should open electrical panel covers. When a panel is open and energised, because of the possibility of arc-flash, all unprotected personnel should be kept behind a calculated and clearly delineated arc-flash boundary.

What to check?

* To keep the task manageable, begin by scanning only MCCs associated with critical assets - those whose failure would threaten people, property or product.

* Scan all components and connections within MCCs with the enclosures open and the equipment running.

* Measure the load at the time of each scan to properly evaluate the measurements against normal operating conditions.

What to look for?

* Look for components that are hotter than similar components under similar loads.

* Look for components that are cooler than similar components under similar loads.

* Doing this may identify broken or undersized wires, defective insulation, faulty (corroded, too loose or over tightened) connections and electrical unbalance among phases.

* Connection related hot spots usually (but not always) appear warmest at the spot of high resistance, cooling with distance from that spot. One source1, reports that 25% of all miscellaneous electrical apparatus failures are caused by loose electrical connections.

* Unbalance, whether normal or out of specification, will appear equally warm throughout the phase or part of the circuit that is overloaded. Harmonic unbalance creates a similar pattern.

* A cooler-than-normal circuit or leg might signal a failed component.

* All electrical currents produce some heat. Heat alone, then, is not an indicator of problems. Equally warm conductors in all three phases represent a 'good' pattern. Differentiation between phases should be investigated.

Record keeping

* Create regular inspection routes that include all key electrical panels, including MCCs.

* Save a thermal image and associated temperature data of each one on computer and track measurements over time.

* This will provide a baseline for comparisons in order to determine whether a hot spot is unusual or not, and to help verify a repair's success.

What represents a red alert?

* Equipment conditions that pose a safety risk should receive the highest repair priority.

* Guidelines provided by the NETA (InterNational Electrical Testing Association) say that when the difference in temperature (DT) between similar components under similar loading exceeds 15°C immediate repairs should be undertaken.

* The same organisation recommends the same action when the DT for a component and ambient air exceeds 40°C.

* Another approach is to treat the imminent failure of any piece of critical equipment as a red alert.

* The same key operations, maintenance and safety personnel who determine which production assets are critical should play important roles in quantifying 'warning' and 'alarm' levels for those assets.

* Set alarm levels for specific equipment on your thermal imager.

The potential cost of failure

* Since MCCs vary so much in complexity, it is difficult to put firm figures on costs for repairs and replacements. However, one European source2 says that the average MCC repair is between 10 000 Euros (R90 000) and 70 000 Euros (R630 000) with replacements costing 80 000 Euros (R720 000) to 100 000 Euros (R900 000).

Follow-up actions

* When a problem is discovered using a thermal imager, use the associated software to document the findings in a report that includes both a digital photograph and a corresponding thermal image of the equipment.

* Following corrective action, use a new thermal image to assess a repair's effectiveness and evaluate the materials and techniques used.

Sources:

1: The website of the Academy of Infrared Thermography at www.infraredelectrical.com/ infraredelectrical_15.html.

2: Ibid.

The information for this Tech Tip was provided by Comtest Distribution.

For more information contact Val Verwer, Comtest Distribution, +27 (0)11 254 2200, [email protected], www.comtest.co.za



Credit(s)



Share this article:
Share via emailShare via LinkedInPrint this page

Further reading:

Oils don’t die, they degrade
Wearcheck Maintenance, Test & Measurement, Calibration
WearCheck explores the main ways lubricants degrade in service and how these degradation modes affect oil performance and machine reliability.

Read more...
Real-time spectrum analyser
Vepac Electronics Maintenance, Test & Measurement, Calibration
The PXE series real-time spectrum analyser covers frequencies up to 20 GHz with a 100 MHz analytical bandwidth and ultra-fast sweep speed, supporting spectrum monitoring, interference finding and RF test and measurement functions.

Read more...
Preserving a French heritage landmark
Omniflex Remote Monitoring Specialists Maintenance, Test & Measurement, Calibration
Omniflex supplied a remotely monitored impressed current cathodic protection system for the Perret Tower in Grenoble, a protected French heritage site, combining 24/7 corrosion protection with integrated surge protection against lightning strikes.

Read more...
Operational efficiencies and safety compliance with preventive maintenance programmes
Maintenance, Test & Measurement, Calibration
Konecranes explains how its Lifecycle Care Preventive Maintenance programme reduces unexpected downtime, improves safety compliance and delivers measurable financial benefits for operators of cranes and lifting equipment across any make or sector.

Read more...
Portable appliance tester
Vepac Electronics Maintenance, Test & Measurement, Calibration
Vepac Electronics’ new portable appliance tester enables precise safety testing of electrical appliances in accordance with DGUV regulation 3 and BetrSichV, with simple three-button operation and battery-powered mobility.

Read more...
Why lubrication fails in mining and what to do about it
Maintenance, Test & Measurement, Calibration
Lubrication Engineers explains the recurring failure points behind mining lubrication problems and how the right product, storage and application practices can improve equipment reliability.

Read more...
When digital twins move from concept to critical tool
IT in Manufacturing System Integration & Control Systems Design Maintenance, Test & Measurement, Calibration
Digital twins are moving out of the lab and onto the mine, the factory floor and the transport network where they predict failures before they happen. Amritesh Anand looks at where they earn their keep, the data and integration work behind them, and the security questions every organisation should ask before switching one on.

Read more...
Why asset level intelligence is now essential for resilient wastewater plants
Schneider Electric South Africa Maintenance, Test & Measurement, Calibration
Sub-Saharan Africa’s wastewater operators face mounting pressure to keep ageing plants running smoothly and meet tougher environmental standards, all while lacking visibility into the health of their medium-voltage (MV) drives and other critical rotating assets. Adding predictive analytics, digital twins and enterprise dashboards enables optimisation across multiple sites, ensuring every drop moves safely and efficiently through the water cycle.

Read more...
How multiple boilers can minimise costly downtime
Maintenance, Test & Measurement, Calibration
Associated Energy Services explains how multi-boiler systems reduce downtime risk for South African manufacturers, covering redundancy planning, fuel source diversification and the strategic management of backup boiler capacity.

Read more...
Field calibration made easy
Instrotech Maintenance, Test & Measurement, Calibration
Instrotech’s locally designed and manufactured Calog calibrator range feature a rugged IP54-rated housing, backlit display with data logging via SD card, and a lithium-ion battery with approximately eight hours of run time.

Read more...









While every effort has been made to ensure the accuracy of the information contained herein, the publisher and its agents cannot be held responsible for any errors contained, or any loss incurred as a result. Articles published do not necessarily reflect the views of the publishers. The editor reserves the right to alter or cut copy. Articles submitted are deemed to have been cleared for publication. Advertisements and company contact details are published as provided by the advertiser. Technews Publishing (Pty) Ltd cannot be held responsible for the accuracy or veracity of supplied material.




© Technews Publishing (Pty) Ltd | All Rights Reserved