By integrating pressure transmitter electronics with the Annubar averaging pitot tube (APT), Rosemount claims it has the highest performing insertion DP flowmeter. This fully integrated flowmeter eliminates the need for fittings, tubing, valves, adapters, manifolds, and mounting brackets, thereby reducing welding and installation time.
Annubar's frontal slot design and shape improve the accuracy and repeatability of the flow measurement points. Tight process control is gained by increased signal strength and reduced signal noise. The T-shaped sensor includes a sealed, pressure-retaining thermowell that permits mass flow in all line sizes with a single pipe penetration. Multivariable technology in gas and steam applications compensates for pressure and temperature variations, which can cause significant flow errors.
The Annubar sensor is designed to prevent wear and blockage in the pipe. The electronics exhibit high stability, allowing up to 10 years between calibrations cycles, providing significant maintenance savings. The non-constricting design of the Annubar sensor creates minimal blockage in the pipe, which reduces permanent pressure loss. Permanent pressure loss can be converted directly into energy savings in the form of compressor cost for gas, electrical cost for pumping liquids, and fuel costs for generating steam.
While orifice plate technology has been the overwhelming choice for flow measurement, it ultimately requires significant straight-pipe for accurate results. Rosemount conditioning orifice plate technology is able to provide high performance with minimal straight-run. Orifice metering has become more flexible than it has been before.
The Rosemount conditioning orifice plate requires less straight-run, significantly reducing material, labour and procurement costs. Engineering time is reduced since the flowmeter can be installed virtually anywhere.
Flowmeter capability
Rosemount flowmeters feature a scalable platform, advanced diagnostics and multivariable capabilities, all allowing the user to reduce operational and maintenance expenditures while improving throughput and utilities management.
How utilities identify water losses in Northern Europe
Flow Measurement & Control
Norwegian leak detection specialist, Ovarro outlines how municipalities are responding to hidden water loss using acoustic monitoring and analysis tools that provide early indications of developing leaks.
Read more...Senix sensors provide flood warnings Instrotech
Flow Measurement & Control
To create the world’s most sophisticated flood monitoring and forecasting system, the US State of Iowa’s Flood Centre (IFC) uses more than 200 Senix ToughSonic 30 and ToughSonic 50 ultrasonic sensors to measure water levels in streams across the state.
Read more...Mastering inline LNG flow monitoring
Flow Measurement & Control
[Sponsored] As global demand for cleaner, more flexible energy sources continues to rise, liquefied natural gas (LNG) stands at the forefront of the energy transition. Engineered for excellence in cryogenic environments, the Anton Paar L-Cor 8000 flowmeter redefines inline LNG flow monitoring.
Read more...Dosing chlorine gas safely and sustainably
Flow Measurement & Control
Chlorine gas is central to a range of industrial processes but is highly dangerous. The solution is the deployment of a system solution for chlorination from Lutz-Jesco.
Read more...Oil monitoring solution drives performance gains for paper mill SKF South Africa
Flow Measurement & Control
By integrating real-time monitoring with precise flow control, SKF’s Flowline oil monitor meters have significantly improved the flow rate control and performance of oil circulation lubrication systems installed on a paper mill.
Read more...Flow measurement in mobile applications ifm - South Africa
Flow Measurement & Control
The SU Puresonic Mobile ultrasonic sensor from ifm is characterised by its displayless design and high temperature resistance. It is ideal for mobile applications and processes with permanent media temperatures of up to 120°C.
Read more...Optimising water quality in a building cooling system ifm - South Africa
Flow Measurement & Control
A leading company in industrial water management has installed water treatment systems that not only optimise water quality but also help customers to improve their processes, thanks to the new insights and actions that can be generated based on the process data collected.
Read more...New uncompromisingly simple flowmeter line for processes Endress+Hauser South Africa
Flow Measurement & Control
The demand for simplicity in commissioning, operation and maintenance in industrial process plants has increased significantly in recent years. The new Proline 10 range of flowmeters from Endress+Hauser meets this requirement without compromise, because simplicity is the top priority.
While every effort has been made to ensure the accuracy of the information contained herein, the publisher and its agents cannot be held responsible for any errors contained, or any loss incurred as a result. Articles published do not necessarily reflect the views of the publishers. The editor reserves the right to alter or cut copy. Articles submitted are deemed to have been cleared for publication. Advertisements and company contact details are published as provided by the advertiser. Technews Publishing (Pty) Ltd cannot be held responsible for the accuracy or veracity of supplied material.