Uncertainties in shore tank ­measurement

April 2015 Flow Measurement & Control

Flowmeter manufacturers are sometimes asked by tank operators why there is a difference in the cumulative measurements from the flowmeters, compared to the inventory measurements from the level gauges in the tank. This article is based on a study carried out for a customer using a Krohne custody transfer metering system, alongside a tank inventory system. It outlines some of the issues, gives a listing of where errors can occur and can accumulate.

Which system do I choose? Ultrasonic flow, turbine flow, or level gauge inventory?

When installed flowmeters are directly compared to shore tank volumes a significant amount of uncertainties has to be considered. Are we comparing a single batch going into the tank for inventory purposes, or a single batch exiting the tank for billing purposes?

In the latter case, multi-beam ultra­sonic meters are the measurement of choice. They do not drift, they are repeatable, and offer a high custody transfer accuracy of 0,15%, which is virtually impossible with any tank inventory system currently installed.

Factors affecting the accuracy of a tank inventory system

The uncertainties most commonly faced when bulk liquids are being measured can be divided into three categories:

1. Spurious error.

2. Systematic error or bias.

3. Random error.

When an uncertainty has been defined, the source of the error has to be investigated and its significance or weighting determined.

Sources of error:

1. The first obvious source of error is the product to be measured. Many influences can be taken into consideration for determining the actual volume of liquid. Generally the higher the viscosity the higher the uncertainty in the measurement.

2. The second common source of error is the uncertainty of the individual instruments required for the measurement.

3. The third potential source of error is the influence of the instrument operator.

4. The fourth source of error is caused by environmental influences on the instruments.

There are basically four important parameters to be considered in shore tank measurement:

1. Accuracy/uncertainty of the applied strapping tables.

2. Accuracy/uncertainty of the applied level measurement procedure.

3. Accuracy/uncertainty of the applied temperature measurement.

4. Accuracy/uncertainty of the applied API tables.

Accuracy of the applied strapping tables

The following aspects of the tank have to be accurately measured:

• The exact dimensions of the tank shell.

• The contours of the tank floor.

• The size and location of ‘dead wood’, ie, struts, ­agitators, and others intruding parts.

• The weight (volume) of the floating roof.

Accuracy of the applied level measurement procedure

To compensate for any human errors, it is preferable to use automatic level gauges. Mechanical gauges have to be calibrated prior to installation and have to be checked periodically using a certified measurement tape. The influence of the uncertainty of level measurement in shore tank operations has frequently been over­estimated; it is common practice to measure a single batch and try to compensate for the delay in start/stop of the level gauge. An accuracy of level measurement of ±2 mm is in most applications the best achievable figure. It is obvious that the influence of the uncertainty of the level gauge depends on the transferred volume, on a batch of 1 metre the influence will reach 0,4 % while for an 8 metres batch it can drop to 0,05 %.

Accuracy of the applied temperature measurement

The influence of temperature on shore tank measurement is frequently underestimated. It cannot be too strongly emphasised that errors in temperature measurement can account for the most significant part of the total error in shore tank measurement. Errors of 2°C in calculating the average shore tank liquid temperature can easily be introduced, resulting in measurement errors of approximate 0,2%. Even if highly accurate temperature measurement devices are applied this deviation can be experienced; and it should be remembered that deter­mining an average temperature of a completely filled shore tank based on a single spot temperature measurement is a common, but difficult operation.

The preferred approach for determining the liquid temperature is to apply multi-spot temperature measurements at different heights in the tank instead of using a single spot temperature at the output of the shore tank.

API table uncertainty

For calculating the GOV (gross observed volume) to GSV (gross standard volume) a VCF (volume correction factor) has to be applied. In general, this VCF is extracted from the dedicated API tables. In practice it is acknowledged that the uncertainty in these API tables is 0,05%, assuming that the correct density is utilised.

Combined uncertainty

When all uncertainties are combined, a consolidated measurement uncertainty can be calculated as presented and based on the calculation, it can be concluded that the impact of the level and VCF uncertainty are not significant components.

General considerations:

• When was the tank calibrated, to what standard and to what accuracy?

• How and where is the temperature measurement being made in the shore tanks?

• Are the temperature instruments calibrated to custody-transfer requirements?

• How is the level measured and to what standard and accuracy?

• Is water interface and sludge an issue?

• What are the dimensions of the tank?

• Calculation routines (strapping tables) for tank?

• Crude oil properties?

• Process conditions?

• Minimum transferred volume?

• Pipeline layout from shore tank terminal to the meter skid?

• Definition of criteria for verification (repeatability)?

• Handling/reporting of verification results?

This article has purposely not dealt with the differences in the level gauging systems, and it is acknowledged that the choice of level gauge (radar, TDR, ultrasonic level, capacitance, float, yo-yo or even level switches) can play a role in the amount of trust the operator can put in his inventory management system.

For more information contact John Alexander, Krohne SA, +27 (0)11 314 1391, [email protected], www.krohne.com



Credit(s)



Share this article:
Share via emailShare via LinkedInPrint this page

Further reading:

Case History 198: Cascade control overcomes valve problems.
Editor's Choice Flow Measurement & Control
There are many processes where it is undesirable for the load to suddenly change quickly, for example in the paper industry. Examples of level control have involved reasonably fast tuning. An example of a level loop tuned this way and responding to a step change in setpoint is given.

Read more...
A reliable water supply: The make or break in building metros across South Africa
VEGA Controls SA Flow Measurement & Control
South Africa’s urban centres encounter substantial water supply challenges. Maintaining stable water infrastructure is essential for the health, economic vitality and well-being of communities.

Read more...
Uncompromising flow rate measurement
Burkert South Africa Flow Measurement & Control
Bürkert’s FLOWave is a hygienic and safe flow measurement solution with many benefits for pharmaceutical or food production processes.

Read more...
Electromagnetic flow measurement
Siemens South Africa Flow Measurement & Control
The SITRANS FM electromagnetic flowmeters from Siemens deliver high-precision volume measurement of electrically conductive liquid applications – from water, wastewater and irrigation to hygienic processes and even mining slurries with magnetic particles.

Read more...
ABB unveils next generation of electromagnetic flowmeters
ABB South Africa Flow Measurement & Control
ABB has launched its latest generation of electromagnetic flowmeters, bringing unmatched accuracy, connectivity and flexibility to industrial and utility applications.

Read more...
Precision measurement for ultra-pure water systems
Flow Measurement & Control
[Sponsored] Ultra-pure water (UPW) is essential in industries where even minor contaminants can impact product quality and process integrity. Anton Paar’s L-Cor Coriolis mass flowmeters provide a highly accurate and hygienic solution by directly measuring the mass of the liquid using the Coriolis effect, ensuring a high level of cleanliness.

Read more...
Inline process solutions for gold mining
Anton Paar Flow Measurement & Control
[Sponsored]The extraction and processing of gold ore requires precision and efficiency to maximise yield and minimise losses. Automation and continuous monitoring of critical process steps are essential to ensure optimal production. Anton Paar offers advanced inline measurement solutions which enable full automation and real-time monitoring of key steps in gold extraction and processing.

Read more...
Magnetic-inductive flow sensor
ifm - South Africa Flow Measurement & Control
The SMF magnetic-inductive flow sensor revolutionises liquid and creamy flow measurement. With IO-Link, it enables digital data transmission, eliminating blind spots in production.

Read more...
Hygienic flow measurement for the food industry
ifm - South Africa Flow Measurement & Control
With the SMF magnetic-inductive flow meter, ifm offers a solution for the hygienic flow measurement of media with variable flow rates through a pipe, such as beer, milk or fruit juice.

Read more...
Case History 197: Bad reboiler temperature control.
Michael Brown Control Engineering Editor's Choice Flow Measurement & Control
It is very important that reboiler temperature controls operate well in petrochemical refineries, or the product quality can really suffer. I was asked to check such a control in a refinery where they were having problems with one of these controls.

Read more...









While every effort has been made to ensure the accuracy of the information contained herein, the publisher and its agents cannot be held responsible for any errors contained, or any loss incurred as a result. Articles published do not necessarily reflect the views of the publishers. The editor reserves the right to alter or cut copy. Articles submitted are deemed to have been cleared for publication. Advertisements and company contact details are published as provided by the advertiser. Technews Publishing (Pty) Ltd cannot be held responsible for the accuracy or veracity of supplied material.




© Technews Publishing (Pty) Ltd | All Rights Reserved