Managing fire risks prevents manufacturing disruption

October 2012 IS & Ex

Companies doing business in the 21st century rely heavily on automation to improve their efficiency and increase competitiveness. This places great emphasis on high value electronic equipment to help perform the tasks that are necessary to achieve the required organisational efficiencies. To this end, an important question becomes: “What will happen to our company if the key electronic equipment fails?” Unfortunately the answer is that it could result in financial losses that may take years to recover. In fact, it could be enough to shut down some companies.

This puts the fire risk of a company into perspective through its high value equipment. Hence, more and more businesses are looking to protect their high value assets against this risk. These assets include server rooms, archive rooms, electricity supply infrastructure, switching and motor control centres and many more.

Gaseous flooding

One of the effective ways to protect such assets against fire is to use the gaseous total flooding method. Essentially, total flooding means flooding the entire room, sealed containing the assets, with a gaseous medium that will inhibit combustion and ultimately extinguish any fire. This method has become a popular solution with both fire engineers and businesses managers.

However, before a business purchases a total flooding system, it should ask the following questions to ensure it will work exactly as required if it is ever needed:

* Is the system fully approved? Does it carry a full system approval to say it will perform the required task? Is there a valid certificate to show this?

* What are the long term implications? How do the Kyoto and Montreal Protocols impact the decision ie, could this system be phased out? What does ISO 14520 say about the various total flooding systems?

* How many cylinders are required and how cost effective is the system? How does it compare with other products?

* What are the costs for refilling? Is this readily available? Are spares readily available?

* Is the system designed to the correct standard?

* Are the suppliers competent?

Based on the above, the potential supplier should respond with the following:

1. A set of flow calculations done by the fire engineer based on a pipe layout, cylinder location and nozzle positions. This should all be based on the relevant engineering standards (ie, ISO 14520, NFPA 2001).

2. The flooding system should be interfaced with an automatic detection system that is designed and installed to the correct standard.

3. The system should be installed to the required standard (ISO 14520 or NFPA 2001). Check that the correct pipe has been used, the pipe fittings are correct and the pipe has been installed correctly.

4. After the installation a room integrity test should be carried out to determine the room’s rate of leakage. This is mandatory for all clean agent gaseous total flooding systems in the standard ISO 14520 Part 1 and SANS 306-4 for carbon dioxide. Based on the room integrity test, over pressurisation venting may be installed.

5. The fire protection system must then be commissioned. What tests were carried out to ensure that the system will work in the event of a fire? Were these tests carried satisfactorily? What records were kept of these tests?

In the event of a fire, the detection system will alert the control room and begin the total flooding sequence. The gas will discharge and inhibit combustion, thus extinguishing the fire. The gas should be retained in the room for a prescribed period of time to prevent re-ignition – room integrity testing must be done annually to ensure this.

Negotiate a service contract with a reputable specialist that ensures regular equipment checks and servicing when required. Post discharge, the servicing contractor will have the cylinders refilled.

For more information contact Samantha Wright, Alien Systems & Technologies, +27 (0)11 949 1157, [email protected], www.astafrica.com



Credit(s)



Share this article:
Share via emailShare via LinkedInPrint this page

Further reading:

New modules for distributed integration of intrinsically safe signals
Beckhoff Automation IS & Ex
Beckhoff provides a compact acquisition solution for intrinsically safe signals up to zone 0/20 with the IP67-protected EtherCAT Box modules of the EPX series.

Read more...
Control and monitoring with only one device
Pepperl+Fuchs IS & Ex
Pepperl+Fuchs has expanded its portfolio of K-System isolated barriers for DIN rail mounting (power rail) with the KCD2-SCS interface module. As the first 2-channel AI/AO intrinsic safety barrier with dual function, the module can be configured individually for analogue input or output control signals.

Read more...
Hazardous area solutions
Extech Safety Systems IS & Ex
SEW-EURODRIVE is revolutionising industrial automation with advanced gear units, decentralised drives and the energy-efficient MOVIGEAR system.

Read more...
Field service regime key for effective PDS/CPS operation
IS & Ex
While their primary objective is to ensure the safety of people, proximity detection system and collision prevention system installations also have a direct bearing on other critical parameters such as equipment availability and productivity.

Read more...
World’s first 5G smartphone for ATEX and IECEx zone 1/21
Extech Safety Systems IS & Ex
i.safe MOBILE has launched the world’s first 5G smartphone for ATEX and IECEx zone 1/21. The intrinsically safe mobile device, which was also developed for use in 5G campus networks, offers companies great flexibility thanks to its wide range of possible applications, especially in the automation sector.

Read more...
Fully Ex-certified access point solutions for wireless communication
Pepperl+Fuchs IS & Ex
Pepperl+Fuchs now offers a wireless access point solution that is fully certified in accordance with ATEX/IECEx standards, and forms the basis for end-to-end Wi-Fi communication in hazardous areas.

Read more...
Secure, digital communication in potentially explosive atmospheres
Pepperl+Fuchs IS & Ex
Consistently digitalised processes in the smart factory are a matter of course today, but not in potentially explosive atmospheres. The systems and devices used in these areas must have optimal protection mechanisms to ensure maximum safety.

Read more...
Functional and compatible intrinsically safe loop approvals
Extech Safety Systems IS & Ex
With all the focus on IS loop approval, it is easy to forget to check that the loop will function correctly to see whether the field device has sufficient power (voltage & current) to operate over the full process range.

Read more...
Upgrade your legacy alarm units
Omniflex Remote Monitoring Specialists IS & Ex
Darren Barratt, sales manager at alarm annunciator specialist Omniflex, explains the drawbacks of leaving outdated rack-based alarm annunciator systems in place, and why an upgrade might be simpler than you would expect.

Read more...
Cathodic protection system for hazardous environments
Omniflex Remote Monitoring Specialists IS & Ex
When NSW Ports in Australia embarked on a two-year programme to rehabilitate the structures and combat corrosion levels at its Bulk Liquid Berth 1, it commissioned Melbourne-based consultancy Infracorr to deliver a bespoke cathodic protection) system. To deliver the system safely, Infraccor engaged cathodic protection specialist Omniflex to support the hazardous area and remote monitoring aspects of the CP system design.

Read more...