Maintenance, Test & Measurement, Calibration


Panel mounted digital process indicator

Technews Industry Guide: Maintenance, Reliability & Asset Optimisation 2020 Maintenance, Test & Measurement, Calibration

The LT1200 panel mount process indicator is a precision digital indicator for interfacing to and measuring most process variables. The LT1200 is capable of measuring and processing variables such as mA, volts, potentiometers, frequency and counting, and also has built-in functions such as an event timer, real-time clock (RTC option required) and a manual analog output station (Analog out option required). The LT1200 also includes a multiple output excitation voltage selection for sensor excitation of two or three wire transmitters, encoders, potentiometers and more.

Calibration of the analog process variables is simply done by either entering in the display range selection or by direct sensor injection calibration. The high bright 6-digit 14-segment LED displays make for easy setup and readability. A simple menu system with built-in help hints allows for easy configuration of display and sensor settings.

A universal mains switch mode power supply (85-264 VAC) is provided as standard but an optional low voltage (10-30 VDC) isolated power supply or a high voltage (25-70 VDC) isolated power supply can be installed. RS-232 communication is supplied as standard with the Modbus RTU and Modbus ASCII protocol. A simple ASCII out protocol is also provided for serial printing and communicating to large displays. A second communication RS-485 interface can be added if required.

The LT1200 also has an analog out, or an isolated analog out, option to generate a precision 0/4-20 mA and 0-10 V analog output signal. Other advanced features include user input linearisation, max/min recording, programmable front push buttons, programmable digital inputs, security menu lockout and advanced digital filtering to provide a truly universal process indicator.


Credit(s)



Share this article:
Share via emailShare via LinkedInPrint this page

Further reading:

Electrostatic spark discharge – when static strikes back
Wearcheck Maintenance, Test & Measurement, Calibration
WearCheck technical manager, Steven Lumley explains how static electricity accumulates in modern low-conductivity lubricants, why compact system designs and fine filtration make ESD more likely, and how to recognise the degradation it leaves behind.

Read more...
High-speed cameras for crash testing
Horne Technologies Maintenance, Test & Measurement, Calibration
Vision Research has expanded its Phantom C-series with two cameras optimised for crash and safety testing, offering 4 and 8 megapixel sensors rated to 170G, up to 1180 frames per second, and Phantom Academy application training planned for South Africa next year.

Read more...
SKF extends remanufacturing expertise to bearing clearance modification
SKF South Africa Maintenance, Test & Measurement, Calibration
Using its clearance modification expertise, SKF helped a mining equipment OEM salvage spherical roller bearing inventory that would otherwise have been scrapped, confirming a new capability within its remanufacturing services and avoiding redundant procurement.

Read more...
When maintenance-system compliance starts replacing plant reliability
Wearcheck Maintenance, Test & Measurement, Calibration
WearCheck ARC division manager, Annemie Willer argues that the greatest threat to effective maintenance is no longer a lack of technology, but the gradual replacement of technical judgement by CMMS compliance, leaving no one owning the machine.

Read more...
Automatic lubrication systems drive mobile mine machine reliability and uptime
SKF South Africa Maintenance, Test & Measurement, Calibration
SKF’s Lincoln P203 progressive lubrication systems are improving reliability and uptime on mobile machines at a Zambian gold mine, with installation of 45 units completing by October 2026.

Read more...
Nitration: the acid you didn’t see coming
Wearcheck Maintenance, Test & Measurement, Calibration
Nitration is as destructive as oxidation in many engines but far less understood. WearCheck technical manager, Steven Lumley explains how nitrogen oxide gases degrade lubricants, why the process is difficult to detect, and what oil analysis can reveal before damage occurs.

Read more...
KSB makes mechanical seals for its own pumps and other brands
Maintenance, Test & Measurement, Calibration
KSB Pumps and Valves is expanding its range of mechanical seals to fit its own pumps and competitor brands. The portfolio covers component and cartridge seals, API 682-compliant systems, slurry and high-pressure seals, and ATEX-certified solutions, supported by refurbishment and field service capabilities.

Read more...
Omniflex delivers ICCP systems in London
Omniflex Remote Monitoring Specialists Maintenance, Test & Measurement, Calibration
Omniflex has supplied impressed current cathodic protection systems for landmark London buildings, protecting reinforced concrete from corrosion and extending the service life of commercial, retail and heritage sites.

Read more...
Modernising acid cooler protection without disrupting production
Omniflex Remote Monitoring Specialists Maintenance, Test & Measurement, Calibration
Omniflex has supplied an advanced anodic protection control system to phosphate producer Foskor, replacing a legacy transformer rectifier system while maintaining uninterrupted production. The distributed PowerView CP solution provides remote monitoring and DCS integration.

Read more...
Engineering partnership delivers longer life for vibrating feeders in mining
Maintenance, Test & Measurement, Calibration
OST-Africa’s combination of VISAM vibrating motors and advanced rubber mounting technology has helped Euro Sales achieve a 30 to 40% increase in component life on vibrating feeders at several major mining operations, with zero mount failures in the first 12 months.

Read more...









While every effort has been made to ensure the accuracy of the information contained herein, the publisher and its agents cannot be held responsible for any errors contained, or any loss incurred as a result. Articles published do not necessarily reflect the views of the publishers. The editor reserves the right to alter or cut copy. Articles submitted are deemed to have been cleared for publication. Advertisements and company contact details are published as provided by the advertiser. Technews Publishing (Pty) Ltd cannot be held responsible for the accuracy or veracity of supplied material.