Flow Measurement & Control


Electromagnetic flowmeter

October 2018 Flow Measurement & Control

Kobold’s new model EPS electromagnetic flowmeter has a standard accuracy of ±0,3% of reading stability of zero. The new developed, microprocessor-controlled UMF2 converter guarantees highest accuracy and is easy to operate via its alphanumeric backlit LCD terminal with six keys, plain text response and plausibility check of entries. Empty-pipe detection, coil current monitoring and plain text error messages guarantee full control over sensor and measuring point at any time. Pulse, status and current outputs, as well as HART communication, are standard features, all of which are electrically isolated. Lining materials, such as hard rubber, soft rubber, EPDM, ceramic, PTFE or PFA, are available. A wide range of standard and special electrode materials are on offer, including stainless steel, Hastelloy, platinum, titanium and tantalum. The EPS is available for nominal diameter from DN10 ... DN1200 and flow velocities up to 10 m/s.

The main features of the EPS are:

• High accuracy: 0,3% of actual.

• Maintenance-free.

• No pressure drop.

• Numerous lining materials.

• Numerous electrode materials.

• Low-cost grounding electrode instead of earthing rings.

The EPS is used to measure the volume flow of liquids, slurries, pastes and other electrically conductive media without any pressure drop. Pressure, temperature, density and viscosity do not affect the volume measurements. However, solid particles and small gas bubbles should be avoided.

For more information contact Instrotech, +27 10 595 1831, [email protected], www.instrotech.co.za



Credit(s)



Share this article:
Share via emailShare via LinkedInPrint this page

Further reading:

Precision measurement for ultra-pure water systems
Flow Measurement & Control
[Sponsored] Ultra-pure water (UPW) is essential in industries where even minor contaminants can impact product quality and process integrity. Anton Paar’s L-Cor Coriolis mass flowmeters provide a highly accurate and hygienic solution by directly measuring the mass of the liquid using the Coriolis effect, ensuring a high level of cleanliness.

Read more...
Rotary atomisers for efficient paint spraying
Instrotech Sensors & Transducers
Painting the bodywork is an integral component of vehicle manufacturing. Keller supplied intrinsically safe pressure transmitters and intrinsically safe temperature sensors to a client producing paint robots for the car industry.

Read more...
Inline process solutions for gold mining
Anton Paar Flow Measurement & Control
The extraction and processing of gold ore requires precision and efficiency to maximise yield and minimise losses. Automation and continuous monitoring of critical process steps are essential to ensure optimal production. Anton Paar offers advanced inline measurement solutions which enable full automation and real-time monitoring of key steps in gold extraction and processing.

Read more...
Magnetic-inductive flow sensor
ifm - South Africa Flow Measurement & Control
The SMF magnetic-inductive flow sensor revolutionises liquid and creamy flow measurement. With IO-Link, it enables digital data transmission, eliminating blind spots in production.

Read more...
Hygienic flow measurement for the food industry
ifm - South Africa Flow Measurement & Control
With the SMF magnetic-inductive flow meter, ifm offers a solution for the hygienic flow measurement of media with variable flow rates through a pipe, such as beer, milk or fruit juice.

Read more...
Case History 197: Bad reboiler temperature control.
Michael Brown Control Engineering Editor's Choice Flow Measurement & Control
It is very important that reboiler temperature controls operate well in petrochemical refineries, or the product quality can really suffer. I was asked to check such a control in a refinery where they were having problems with one of these controls.

Read more...
Precision measurement for ultra-pure water systems
Anton Paar Flow Measurement & Control
[Sponsored] Ultra-pure water (UPW) is essential in industries where even minor contaminants can impact product quality and process integrity. Anton Paar’s L-Cor Coriolis mass flowmeters provide a highly accurate and hygienic solution by directly measuring the mass of the liquid using the Coriolis effect, ensuring a high level of cleanliness.

Read more...
Eliminating splashbacks, spills and early shutoffs in ultra high-flow fuelling
Flow Measurement & Control
Husky Corporation has unveiled the latest innovation in fuelling technology with its newly designed StreamShaper for ultra high-flow applications, which minimises early shutoffs and splashback spills.

Read more...
Radiometric density measurements
Mecosa Flow Measurement & Control
Radiometric density measurements are used wherever conventional measurement techniques fail. Successful applications can be found in a wide variety of industries, especially where harsh process environments and difficult measuring conditions prevail.

Read more...
Battery-powered magmeter
Flow Measurement & Control
The RWEM/D battery-powered electromagnetic flow meter from Royce Water Systems is ideal for water and wastewater systems located at remote sites.

Read more...