Flow Measurement & Control


Ultrasonic flowmeter with temperature measurement

May 2018 Flow Measurement & Control

Endress+Hauser’s Prosonic Flow E 100, an ultrasonic flowmeter is of high-quality industrial design, which allows reliable monitoring of industrial water, cooling water or condensate, regardless of conductivity, and at temperatures up to 150°C.

The robust instrument 100 is made entirely of stainless steel and is perfectly suited for long term operation in rough conditions. Its range of operation generally allows for process pressures up to 25 bar as well as process temperatures up to 150°C. For the flow measurement of water in steam circuits this is the ideal flowmeter. In addition, the ultrasonic flow measurement ensures – independent of the prevailing pressure and temperature conditions – a high measuring accuracy as well as a high flow range.

Greater efficiency due to integrated temperature measurement

In steam circuits, plant operators place a great deal of value on achieving optimal energy and cost efficiency. As a multivariable flowmeter, Prosonic Flow E 100 does not just detect flow, but it also detects the fluid temperature, for example, of water in the condensate return to the boiler. This allows for permanent monitoring and controlling of feed water temperature, resulting in a higher process efficiency in the boiler.

Web server allows direct data access onsite

The Proline 100 transmitter is equipped with a web server as standard. Using an Ethernet cable and a laptop, users have direct and complete access to all diagnostic, configuration and device data onsite, without needing additional software or hardware. This enables targeted maintenance and service thus saving time.

Heartbeat Technology for the highest operational safety

A further highlight is Heartbeat Technology. Integrated into all Proline devices, this checking function enables permanent self-diagnosis, along with extensive monitoring of the values measured, and providing a traceable certificate for verification during operation. This reduces the complexity and risks involved in a plant and therefore increased safety.

HistoROM simply unforgettable

The unique data handling concept (HistoROM) ensures maximum data safety before, during and after a service call. All calibration data and transmitter parameters are stored securely on the HistoROM data memory and are automatically reloaded after a maintenance event. This makes the exchange of spare parts easy and reduces downtime.

For more information contact Frans van den Berg, Endress+Hauser, +27 (0)11 262 8000, [email protected], www.za.endress.com



Credit(s)



Share this article:
Share via emailShare via LinkedInPrint this page

Further reading:

Mastering inline LNG flow monitoring
Flow Measurement & Control
[Sponsored] As global demand for cleaner, more flexible energy sources continues to rise, liquefied natural gas (LNG) stands at the forefront of the energy transition. Engineered for excellence in cryogenic environments, the Anton Paar L-Cor 8000 flowmeter redefines inline LNG flow monitoring.

Read more...
Cleaning solutions for optical sensors
Endress+Hauser South Africa Sensors & Transducers
Achieving accurate and continuous process visibility requires reliable sensor performance, even in challenging media. Endress+Hauser’s CYR51 mechanical cleaning unit addresses these challenges by providing stable, automated cleaning of turbidity and UV-Vis absorption sensors.

Read more...
Magnetic-inductive flowmeter with effective compact electronics and IO-link
Instrotech Flow Measurement & Control
KOBOLD has combined two of its proven components, the successful type MIK magnetic-inductive flow meter and the popular U-PACE compact electronics, creating an exciting new compact flow instrument at the best price.

Read more...
Dosing chlorine gas safely and sustainably
Flow Measurement & Control
Chlorine gas is central to a range of industrial processes but is highly dangerous. The solution is the deployment of a system solution for chlorination from Lutz-Jesco.

Read more...
Oil monitoring solution drives performance gains for paper mill
SKF South Africa Flow Measurement & Control
By integrating real-time monitoring with precise flow control, SKF’s Flowline oil monitor meters have significantly improved the flow rate control and performance of oil circulation lubrication systems installed on a paper mill.

Read more...
Cutting-edge sensor technology
Endress+Hauser South Africa Sensors & Transducers
The advantage of Endress+Hauser’s Memosens technology is that digitised measured values and sensor information are transmitted via a non-contact connection from the sensor to the cable, and as a digital signal to the transmitter.

Read more...
Flow measurement in mobile applications
ifm - South Africa Flow Measurement & Control
The SU Puresonic Mobile ultrasonic sensor from ifm is characterised by its displayless design and high temperature resistance. It is ideal for mobile applications and processes with permanent media temperatures of up to 120°C.

Read more...
Optimising water quality in a building cooling system
ifm - South Africa Flow Measurement & Control
A leading company in industrial water management has installed water treatment systems that not only optimise water quality but also help customers to improve their processes, thanks to the new insights and actions that can be generated based on the process data collected.

Read more...
Ensuring clean and safe water
Endress+Hauser South Africa Editor's Choice Analytical Instrumentation & Environmental Monitoring
Endress+Hauser’s comprehensive range of disinfection sensors is designed to monitor and control disinfectant levels in water treatment processes.

Read more...
Enhancing gold leaching efficiency
Endress+Hauser South Africa Sensors & Transducers
Endress+Hauser offers a range of advanced technologies designed to enhance the stability and accuracy of pH and dissolved oxygen measurements on gold processing plants.

Read more...









While every effort has been made to ensure the accuracy of the information contained herein, the publisher and its agents cannot be held responsible for any errors contained, or any loss incurred as a result. Articles published do not necessarily reflect the views of the publishers. The editor reserves the right to alter or cut copy. Articles submitted are deemed to have been cleared for publication. Advertisements and company contact details are published as provided by the advertiser. Technews Publishing (Pty) Ltd cannot be held responsible for the accuracy or veracity of supplied material.




© Technews Publishing (Pty) Ltd | All Rights Reserved