IS & Ex


HAZOP and Safety Integrity overview

May 2016 IS & Ex

It has been some 15 years since the introduction of the Functional Safety Management standards of IEC 61508 and 61511, with most international organisations and operating facilities now fully up to speed on the implementation of these safety standards. They allow a more flexible approach in assessing the protection requirements based on applicable risk, as opposed to the previous prescriptive standards of the past and allow the safety design review team to determine ‘how safe is safe’. The functional safety management covers a number of steps or phases during the project execution, which are described in the Functional Safety Lifecycle Model. This technical abstract briefly describes some of these phases applicable to hazard analysis and SIL determination.

HAZOP study

The HAZOP and SIL review timing is important so as to limit the amount of possible design rework, and will normally be conducted prior to the project detailed engineering design phase. The primary objective of a HAZOP is to identify hazardous deviations from design intent in the process itself or associated process equipment and operability, then recommend corrective actions by a team of knowledgeable persons of different disciplines. An Alarm Rationalisation review is also required to confirm if all alarms are necessary and to assign alarm prioritisation, it is also important to reduce operator ‘alarm floods’ during process upsets by various suppression methods.

SIL assignment

To determine just how much applicable safety design is required to be applied, a Safety Integrity Level (SIL) is determined, preferably as part of the HAZOP, which is in relation to the perceived risk of probable frequency of a dangerous event occurring (protection demand) and its likely or credible consequence. There are four SIL grades or requirements based on the average probability of failure on demand (PFDavg), i.e. safety availability or failure rate per hour, and each level increases by one order of magnitude which is indicated by the Risk Reduction Factor (RRF). SIL 1 is the lowest and most common, with SIL 4 being the highest and rarely seen in the normal process industries. The SIL Review is a risk assignment in a structured sequence to determine the required SIL for a specific safety application, and if a SIF is needed to form part of this protection. We need to address three variable attributes in a SIL assignment, these are personnel safety, the environment and financial loss, and the highest SIL applicable to these three will be used to design the safety protection required and any applicable SIF. The results are determined using a Risk Graph calibrated to match a client’s or facility owner’s specific risk aversion.

SIL assessment

For each SIF, a Safety Requirements Specification (SRS) needs to be developed to ensure that the SIF meets the overall SIS design requirements and enables the SIS ESD engineering contractor and safety system supplier to configure the SIFs. Once the SIF/SIL requirements have been determined, each SIF loop, which includes the sensor or transmitter, logic solver and the final element, must be evaluated to ensure that the design meets the required SIL. This involves some complex calculations based on the SIF architecture and requires all SIF loop component failure data to be entered.

Installation and operation

Following the SIS design and procurement, one of the most important phases is the Factory Acceptance Test (FAT), where each SIF is fully tested and documented using the SIF SRS and associated functional logic diagrams. All sensor input ranges and trip alarm settings are checked together with communications to the DCS operator displays. Once delivered to site, this is followed by a Site Acceptance Test (SAT) consisting of full loop simulation. It is the author’s opinion that in general, the largest risk to plant and personnel is not with the initial safety systems design, but with the operating company and how well they manage and maintain their installed safety systems.

Interested readers can download the full paper at http://instrumentation.co.za/+J887

For more information contact RJ (Dick) Perry, +27 (0)83 641 0799, [email protected]





Share this article:
Share via emailShare via LinkedInPrint this page

Further reading:

Cybersecurity for potentially explosive areas
Phoenix Contact IS & Ex
The Cellulink outdoor cellular router product range from Phoenix Contact is being extended. New versions are now also available that have been specially developed for use in Zone 2 potentially explosive areas.

Read more...
Windows tablets for hazardous areas
Extech Safety Systems IS & Ex
i.safe Mobile has expanded its intrinsically safe product range with the launch of the IS945.x series rugged Windows tablets, designed for use in hazardous and demanding industrial environments.

Read more...
Strengthening safety, skills and operational resilience during strategic shutdowns in petrochemical plants
IS & Ex
In the petrochemical industry, shutdowns are high-stakes operations that play a vital role in maintaining plant performance, safety and compliance. A well-executed shutdown helps prevent unplanned outages, minimises costly downtime and keeps operations running efficiently long after production resumes.

Read more...
Kollmorgen expands hazardous location portfolio with AKME servo motors
IS & Ex
With the most compact sizes, high power density, a wide range of mounting and encoder options, and ATEX and IECEx certifications, Kollmorgen’s new AKME servo motors deliver exceptional performance and versatility in hazLoc applications.

Read more...
Hazardous area inspections
Extech Safety Systems IS & Ex
The i.safe MOBILE IS940.1 tablet from Extech delivers the performance of a modern Android device, but in a package designed from the ground up for hazardous areas.

Read more...
Unified endpoint management in hazardous industrial environments
Extech Safety Systems IS & Ex
The strategic integration of SafeUEM‘s comprehensive end-point management platform with i.safe MOBILE‘s certified intrinsically safe devices delivers a unified solution specifically engineered to address the challenges of managing technology in hazardous industrial settings.

Read more...
A lesson in the history and evolution of industrial safety systems
Schneider Electric South Africa IS & Ex
One only has to briefly page through the annals of our industrial history to come across truly hair-raising stories of safety systems failing or underperforming with catastrophic repercussions. Fortunately, industrial safety in the last few decades has undergone some truly profound development.

Read more...
Windows tablets for Zone 1/21, Zone 2/22 and mining
Extech Safety Systems IS & Ex
Extech is expanding its portfolio with the Windows-based tablets IS945.1, IS945.2, and IS945.M1. For the first time, EX certification is combined with full Windows compatibility, without compromising on software or security.

Read more...
Certified safe power for hazardous industrial environments
Conical Technologies IS & Ex
When working in high-risk environments like oil and gas, petrochemical plants or other hazardous industrial zones, safety isn’t just important, it’s essential. That’s why Traco Power developed the TIB-EX series of DIN rail power supplies, purpose-built to deliver reliable power even in the toughest conditions.

Read more...
Parker strengthens explosion safety
IS & Ex
Parker Hannifin has announced that its 37 mm Ex d m coils have attained new ATEX and IECEx Type Examination Certificates according to the latest explosion protection standards.

Read more...









While every effort has been made to ensure the accuracy of the information contained herein, the publisher and its agents cannot be held responsible for any errors contained, or any loss incurred as a result. Articles published do not necessarily reflect the views of the publishers. The editor reserves the right to alter or cut copy. Articles submitted are deemed to have been cleared for publication. Advertisements and company contact details are published as provided by the advertiser. Technews Publishing (Pty) Ltd cannot be held responsible for the accuracy or veracity of supplied material.




© Technews Publishing (Pty) Ltd | All Rights Reserved