Flow Measurement & Control


Krohne’s Waterflux battery-powered water meter

October 2014 Flow Measurement & Control

Krohne’s Waterflux is an electromagnetic flowmeter for applications in the field of water and wastewater. As a result, it is designed for custody transfer according to European Directive MI-001 and the measuring accuracy reflects the specifications of the ISO/EN, MI-001 and OIML standards. The adjustable operating frequency of 1 to 1/20 Hz guarantees reliable measurement results with rapid inflow and outflow rates.

Typical applications for the Waterflux include:

* Drinking water billing.

* Billing of ground water consumption for irrigation systems.

* Distribution network monitoring.

* Pipeline leakage detection systems.

* Water measurement in wells and transfer chambers.

Unobstructed pipe cross section

The true quality of a water meter lies in its measuring section, which determines whether the instrument can deliver precise, repeatable measurement results even in problematic applications such as suspended particles and solids in the water.

The unique design of the Waterflux, consisting of a rectangular cross section, optimised stainless steel electrodes and a homogeneous magnetic field, forms the basis for a flow-optimising pipe cross section and thereby provides reliable measurements that are largely independent of the flow profile.

The advantage is that Waterflux can measure flow bi-directionally. Also, users can customise the measuring frequency specifically to the application thus ensuring that the measurement results are always accurate, even when the flows are changing quickly.

The lining of the measuring tube is made of Rilsan, a material that is resistant to corrosion, ageing and abrasion. As a result, Waterflux is a food-grade flowmeter which complies with KTW, DVGW, WRc and NSF as well as ACS and is thus also approved for potable water.

Saving in installation and maintenance

Pricing is always an important criterion in the selection of a meter. Increasingly companies focus on the total cost of ownership including the purchase price, the costs of inaccuracy, under registration, and installation and maintenance costs. Typical mechanical meters have internal moving parts and are subject to wear and their performance deteriorates over time.

Electromagnetic water meters maintain their accuracy over time and due to their robust construction the time spent on routine maintenance and service activities can be reduced to a minimum. Being obstruction free also offers another important benefit as electromagnetic flowmeters cause only negligible pressure loss in the distribution network.

For more information contact John Alexander, Krohne SA, +27 (0)11 314 1391, [email protected], www.krohne.com



Credit(s)



Share this article:
Share via emailShare via LinkedInPrint this page

Further reading:

Hygienic ultrasonic flow sensor
ifm - South Africa Flow Measurement & Control
The SU Puresonic Hygienic ultrasonic sensor from ifm detects flows of conductive and non-conductive media with high precision.

Read more...
VEGA pressure instrumentation supports resilient water network management
VEGA Controls SA Pressure Measurement & Control Flow Measurement & Control
As rapid urbanisation and climate pressures strain water networks across Africa, accurate real-time pressure monitoring has become a strategic necessity. VEGA’s pressure instrumentation helps utilities reduce losses, protect infrastructure and meet sustainability targets.

Read more...
Reducing fluid control and automation complexity in pharma process development
Flow Measurement & Control
Designing and building pharmaceutical processes or skids demands close coordination between mechanical, electrical, instrumentation and automation engineering teams.

Read more...
Flow imaging microscopy for the early detection of harmful algal blooms
Yokogawa South Africa Flow Measurement & Control
Yokogawa’s advanced flow imaging microscopy technology, FlowCam is helping utilities move from reactive treatment to proactive prevention of harmful algal blooms in reservoirs, dams and freshwater sources.

Read more...
Never waste a drop
Flow Measurement & Control
Manufacturers of pumps, valves and related equipment have an important role to play when systems for water are being designed or upgraded and should be included at every stage of a project to ensure that the work is carried out within the equipment’s capabilities.

Read more...
Ultrasonic flow meters
ifm - South Africa Flow Measurement & Control
The ultrasonic flow meter of the SU series from ifm - South Africa monitors liquid media such as water, glycol solutions or industrial oils. It detects the three process categories volumetric flow quantity, consumed quantity and medium temperature.

Read more...
How utilities identify water losses in Northern Europe
Flow Measurement & Control
Norwegian leak detection specialist, Ovarro outlines how municipalities are responding to hidden water loss using acoustic monitoring and analysis tools that provide early indications of developing leaks.

Read more...
Senix sensors provide flood warnings
Instrotech Flow Measurement & Control
To create the world’s most sophisticated flood monitoring and forecasting system, the US State of Iowa’s Flood Centre (IFC) uses more than 200 Senix ToughSonic 30 and ToughSonic 50 ultrasonic sensors to measure water levels in streams across the state.

Read more...
Mastering inline LNG flow monitoring
Flow Measurement & Control
[Sponsored] As global demand for cleaner, more flexible energy sources continues to rise, liquefied natural gas (LNG) stands at the forefront of the energy transition. Engineered for excellence in cryogenic environments, the Anton Paar L-Cor 8000 flowmeter redefines inline LNG flow monitoring.

Read more...
Magnetic-inductive flowmeter with effective compact electronics and IO-link
Instrotech Flow Measurement & Control
KOBOLD has combined two of its proven components, the successful type MIK magnetic-inductive flow meter and the popular U-PACE compact electronics, creating an exciting new compact flow instrument at the best price.

Read more...









While every effort has been made to ensure the accuracy of the information contained herein, the publisher and its agents cannot be held responsible for any errors contained, or any loss incurred as a result. Articles published do not necessarily reflect the views of the publishers. The editor reserves the right to alter or cut copy. Articles submitted are deemed to have been cleared for publication. Advertisements and company contact details are published as provided by the advertiser. Technews Publishing (Pty) Ltd cannot be held responsible for the accuracy or veracity of supplied material.