Maintenance, Test & Measurement, Calibration


Apollo establishes a new approach to PAT

April 2013 Maintenance, Test & Measurement, Calibration

Seaward has announced its latest electrical safety tester that establishes a new approach to portable appliance testing (PAT). The innovative new Apollo 600 is equipped with onboard risk assessment tools to assist the user and ensure a proportionate response to the inspection and testing of electrical equipment.

The new multi-purpose PAT tester combines electrical testing with sophisticated safety data collection and handling features, including an onboard digital camera, to help those involved in maintaining safety in the workplace to demonstrate compliance with all the latest guidance on inspection and testing programmes. In this way, the combined risk assessment and electrical safety inspection and testing capabilities of Apollo 600 have been specially designed to mirror the latest advice provided by the UK Codes of Practice.

The new guidance stresses the importance of taking a structured approach to risk assessment for the determination of equipment inspection and testing intervals. This puts a new emphasis on the roles of the duty holder and the person performing the inspection and testing in the determination of retest intervals and the management of test results.

The Apollo 600 is designed to assist in this process by combining all the electrical safety testing functions of a conventional PAT tester with an integral risk assessment tool and a digital camera to capture images for inclusion in risk and inspection records, and a retest calculation aid.

The new instrument includes all of the electrical safety tests required by the IET Code of Practice including, earth continuity, insulation resistance at 250 V or 500 V, protective conductor current, touch current, IEC lead polarity and portable RCD trip time, without the risk of tripping the installation RCD.

In addition to testing plug in appliances, Apollo 600 is fully equipped to test permanently connected and three-phase electrical equipment as required by the new Code of Practice.

For broader safety requirements, the new concept tester can also record a wide range of other health and safety inspections and tests, including fire detection and alarm systems, and emergency lighting checks, together with the ability to output a wide range of safety labels and test reports and certificates.

The introduction of the Apollo 600 is complemented by upgraded test results management software in the form of the PATGuard 3 program. The improved features of this software include an intuitive user Interface that allows data to be downloaded quickly and reports to be created easily.

The software enables users to tag photographs to assets, sites, locations and test results with the built-in universal risk assessment tool allowing full recording and reporting of hazards and any corrective actions needed.

As well as comprehensive PAT reports, PATGuard 3 can also generate additional reports on health and safety matters, including fire alarm systems and emergency lighting. The new Apollo 600 and PATGuard 3 software are the latest additions to a comprehensive range of PAT testers, accessories and training materials provided by Seaward to help maintain electrical safety in the workplace.

For more information contact Justin Clarkson, Test Instruments Africa, +27 (0)11 608 8541, [email protected], www.testinstrumentsafrica.com





Share this article:
Share via emailShare via LinkedInPrint this page

Further reading:

UV water treatment system
Maintenance, Test & Measurement, Calibration
bestUV is an innovative manufacturer of professional ultraviolet (UV) water treatment systems for industrial markets.

Read more...
RS PRO a key partner for planned maintenance
RS South Africa Maintenance, Test & Measurement, Calibration
RS PRO, the own-brand of RS, offers a comprehensive selection of over 80 000 products spanning all industries and technologies.

Read more...
WearCheck leads the way in condition monitoring
Wearcheck Maintenance, Test & Measurement, Calibration
Minimising maintenance costs of mining and power-generating machinery and maximising its operational efficiency – these goals form the foundation of the proactive/preventive maintenance services provided by the expert technicians at condition monitoring specialist, WearCheck.

Read more...
Collect data three times faster
SKF South Africa Maintenance, Test & Measurement, Calibration
SKF has extended its renowned Microlog Analyzer family of data collection devices with the addition of the Microlog Analyzer dBX. Currently SKF’s most powerful diagnostic tool, this cutting-edge device redefines diagnostic capabilities, enabling users to take measurements three times faster than its predecessor.

Read more...
Integrated liners for the mining industry
Maintenance, Test & Measurement, Calibration
Multotec has developed a range of composite integrated mill liners in response to the needs of local and international mining clients.

Read more...
The criticality of maintenance in the water and wastewater segment
Schneider Electric South Africa Maintenance, Test & Measurement, Calibration
In a time of water shedding, climate change and ageing infrastructure, the importance of maintenance and support in the water and wastewater segment cannot be overstated.

Read more...
How dry ice blasting is revolutionising the mining industry
Maintenance, Test & Measurement, Calibration
Dry ice blasting has emerged as a game-changing technology for the mining industry, offering a range of advantages that are reshaping traditional cleaning methods.

Read more...
Quality test tools save costs at pulp and paper mill
Comtest Editor's Choice Maintenance, Test & Measurement, Calibration
A case study on how preventive maintenance and a few good test tools avoided unnecessary motor replacements at a pulp and paper company.

Read more...
The logical solution to oil and gas industry corrosion
Maintenance, Test & Measurement, Calibration
The consequences of corrosion in the oil and gas industry can be astronomical. The simple culprit is metal reacting with oxygen and moisture, degrading it back to its natural state.

Read more...
Lube tip: foaming is affected by oil level
Wearcheck Maintenance, Test & Measurement, Calibration
In a circulating system, it is crucial to check the oil level before introducing anti-foam agents to address a foaming problem.

Read more...