Whenever electrical equipment is required for use in hazardous environments, such as those that are commonplace in the chemical, oil and gas, mining and processing industries, they must be designed with intrinsic safety in mind. This stops them acting as potential ignition sources in plant areas containing volatile dusts, gases or liquids. Darren Barratt, product sales manager at alarm and event management specialist, Omniflex outlines the importance and key aspects of intrinsic safety design.

Electrical components designed for use in hazardous environments must follow the principles of intrinsic safety, which allow for safe operation of electrical equipment in hazardous areas by limiting the electrical and thermal energy available for ignition. Components need to be selected carefully so any failure does not compromise safety, along with balancing functional and performance requirements with those safety considerations.

This includes any constructional requirements that may be required, along with considerations surrounding the separation of PCBs between components and terminals, the current rating and PCB tracks and the type of environment they will operate in.

Hazardous environments are separated into three zones. Zone 0 is defined as a constant explosive environment in normal operating conditions, while Zone 1 indicates an occasionally explosive atmosphere, usually caused by things such as leakage and maintenance operations. Here, energy limiting practices and considerations for possible component failure become mandatory due to a higher possibility of explosion that comes with frequent exposure to flammable or explosive materials. Finally, Zone 2 is indicative of an area in which an explosive atmosphere is not likely to occur in normal operation and, if it occurs, will only exist for a short time.

Regulatory considerations

Intrinsically safe instrumentation is required in environments where there is a significant risk of explosion. This includes gas and oil rigs, refineries, mining and chemical factories. Equipment used in these settings must adhere to strict international standards and manufacturers must stay updated with changing regulations. Electrical components in the European Union must adhere to ATEX certification.

Any batch of products can be verified in a testing lab against the original approval – although manufacturers can self-certify equipment for Zone 2 components as standards can be verified in the EU. For the more explosive areas of Zones 0 and 1, equipment requires testing by an ATEX-approved notified body.

Alarm annunciation

Alarm annunciators in potentially explosive environments can help avert any hazardous events. They inform operators of potential problems that must be addressed, notifying them of a safety action to be carried out. In turn, this prevents any unplanned downtime at a facility. So, as well as bringing about safety features, the annunciators can contribute to cost savings.

Rather than operating on a supervisory control and data acquisition (scada) system or other computer systems, alarm annunciators provide an independent form of detection for the safety of a facility. While performing the same role as a standard alarm annunciator in alerting operators to a problem, the devices can be developed and manufactured by specialists to ensure less risk of electrical sparks, reducing the risk of any dangerous events or downtime that halts production or output.

Omniflex’s Omni16C-EX integral alarm annunciator and displays are an example of the intrinsically safe electrical equipment the company can provide for international markets. With ATEX certification, the annunciators can be used in Zone 2 areas notifying operators of dangerous situations in potentially hazardous areas, and alerting any staff operating in that area. Once mounted, the Omni16C-EX is fully protected in a protective enclosure to allow location in hazardous areas.

Omniflex’s certified facility in Durban manufactures the Omni16C-EX integral alarm annunciator which offers protection and ensures critical alerts reach your team without compromising performance or safety in environments including gas and oil rigs, chemical factories and mining operations.

To find out more about how Omniflex’s solutions can reduce downtime and enhance operational safety, visit its alarm sector overview document at https://tinyurl.com/4u7nsrsf

For more information contact Omniflex Remote Monitoring Specialists, +27 31 207 7466, [email protected], www.omniflex.com




Share this article:
Share via emailShare via LinkedInPrint this page

Further reading:

New modules for distributed integration of intrinsically safe signals
Beckhoff Automation IS & Ex
Beckhoff provides a compact acquisition solution for intrinsically safe signals up to zone 0/20 with the IP67-protected EtherCAT Box modules of the EPX series.

Read more...
Control and monitoring with only one device
Pepperl+Fuchs IS & Ex
Pepperl+Fuchs has expanded its portfolio of K-System isolated barriers for DIN rail mounting (power rail) with the KCD2-SCS interface module. As the first 2-channel AI/AO intrinsic safety barrier with dual function, the module can be configured individually for analogue input or output control signals.

Read more...
Hazardous area solutions
Extech Safety Systems IS & Ex
SEW-EURODRIVE is revolutionising industrial automation with advanced gear units, decentralised drives and the energy-efficient MOVIGEAR system.

Read more...
Field service regime key for effective PDS/CPS operation
IS & Ex
While their primary objective is to ensure the safety of people, proximity detection system and collision prevention system installations also have a direct bearing on other critical parameters such as equipment availability and productivity.

Read more...
World’s first 5G smartphone for ATEX and IECEx zone 1/21
Extech Safety Systems IS & Ex
i.safe MOBILE has launched the world’s first 5G smartphone for ATEX and IECEx zone 1/21. The intrinsically safe mobile device, which was also developed for use in 5G campus networks, offers companies great flexibility thanks to its wide range of possible applications, especially in the automation sector.

Read more...
Fully Ex-certified access point solutions for wireless communication
Pepperl+Fuchs IS & Ex
Pepperl+Fuchs now offers a wireless access point solution that is fully certified in accordance with ATEX/IECEx standards, and forms the basis for end-to-end Wi-Fi communication in hazardous areas.

Read more...
Secure, digital communication in potentially explosive atmospheres
Pepperl+Fuchs IS & Ex
Consistently digitalised processes in the smart factory are a matter of course today, but not in potentially explosive atmospheres. The systems and devices used in these areas must have optimal protection mechanisms to ensure maximum safety.

Read more...
Functional and compatible intrinsically safe loop approvals
Extech Safety Systems IS & Ex
With all the focus on IS loop approval, it is easy to forget to check that the loop will function correctly to see whether the field device has sufficient power (voltage & current) to operate over the full process range.

Read more...
Upgrade your legacy alarm units
Omniflex Remote Monitoring Specialists IS & Ex
Darren Barratt, sales manager at alarm annunciator specialist Omniflex, explains the drawbacks of leaving outdated rack-based alarm annunciator systems in place, and why an upgrade might be simpler than you would expect.

Read more...
Cathodic protection system for hazardous environments
Omniflex Remote Monitoring Specialists IS & Ex
When NSW Ports in Australia embarked on a two-year programme to rehabilitate the structures and combat corrosion levels at its Bulk Liquid Berth 1, it commissioned Melbourne-based consultancy Infracorr to deliver a bespoke cathodic protection) system. To deliver the system safely, Infraccor engaged cathodic protection specialist Omniflex to support the hazardous area and remote monitoring aspects of the CP system design.

Read more...