Crusher gap measurement

February 2021 Maintenance, Test & Measurement, Calibration

Developed by Mintap, based in Perth, Western Australia, the Closed Side Setting (CSS) measurement device – the C-Gap – is now available through South African-based Control Systems Rustenburg. C-Gap offers accuracy, safety and reliability to the quarrying and mining industries for the measurement of the CSS in gyratory, jaw and cone crushers.

The C-Gap works by placing selected high-density rubber hollow bulbs into the crusher mantle. When the bulb is squeezed between the fixed and moving plates, the air pressure in the hose increases, then, by correlating the air pressure through manual calibration, the CSS is measured between 7 mm and 220 mm with an accuracy of 1 mm.

The process of measuring the CSS on all four sides of a cone crusher takes less than five minutes and requires only one operator. Jaw and gyratory crushers are about the same.

The C-Gap effectively replaces current methods of CSS measurement, namely the use of lead weights, steel drums, aluminium or clay balls, or manual measurement. Because the procedure is so quick and easy, the CSS can be measured every shift on all crushers, ensuring consistent crusher operation by achieving targeted set points across all crews.

Maintaining the CSS

To date, there has not been a quick, accurate and safe way to measure the CSS in larger primary crushers; the CSS on these crushers is usually measured during shutdowns only, meaning it runs unchecked for potentially weeks at a time. This results in reduced crusher performance, placing increased emphasis on downstream circuits.

By measuring every shift, the CSS can be maintained and mantle wear can be documented, assisting with service planning. Operators on sites using the C-Gap commended its safety advantage over the lead weights. Through site comparative trials they noted the C-Gap had an improved accuracy over the use of traditional means. Cost-benefit analyses of sites that currently use lead weights have shown a payback within six months of purchase, when one considers the cost and safe disposal of these. Sites that do not use lead weights enjoy the improved accuracy of the C-Gap.

For more information contact JP van Dyk, Control Systems Rustenburg/Steelpoort, +27 87 230 8391, csrsales@controlsystemsrust.co.za, www.controlsystemsrust.co.za




Share this article:
Share via emailShare via LinkedInPrint this page

Further reading:

Extensive range of test instruments from RS Components
March 2021, RS Components SA , Maintenance, Test & Measurement, Calibration
The RS range includes digital multimeters, voltage/current calibrators, insulation testers, temperature calibrators, and voltage indicators.

Read more...
In situ control valve testing
April 2021, Comtest , Maintenance, Test & Measurement, Calibration
Fluke’s valve tester allows technicians to conduct checks of control valves while they are in place.

Read more...
SICK Automation introduces berm monitoring system
February 2021, SICK Automation Southern Africa , Maintenance, Test & Measurement, Calibration
The SICK Advanced Object Detection LiDAR System (AOS LiDAR) offers high reliability for outdoor applications.

Read more...
Belt tracker eliminates conveyor problems
February 2021 , Maintenance, Test & Measurement, Calibration
The Scrapetec PrimeTracker helps address problems associated with belt conveyors, including misalignment, abrasion and belt damage.

Read more...
Wireless machine monitoring
February 2021, SKF South Africa , Maintenance, Test & Measurement, Calibration
The SKF Enlight Collect monitoring system combines SKF’s knowledge in machine health monitoring with LumenRadio’s patented network technology.

Read more...
See sound and locate invisible threats
February 2021, Comtest , Maintenance, Test & Measurement, Calibration
Fluke’s new ii910 precision acoustic imager detects corona, partial discharge and gas, steam and compressed air leaks, which can all hurt production uptime.

Read more...
Keep our bridges standing
February 2021, Omniflex Remote Monitoring Specialists , Maintenance, Test & Measurement, Calibration
Omniflex’s iGAL galvanic CP monitor is battery powered and so can be installed quickly and easily. It is as simple as connecting up the anodes, reference electrode half-cells, and switching it on.

Read more...
Keeping the clean room more than clean
January 2021, GHM Messtechnik SA , Maintenance, Test & Measurement, Calibration
The Delta OHM HD50CR multi-functional clean room logger/transmitter device offers the user highly accurate clean room monitoring and documentation for quality purposes.

Read more...
Machine health monitoring
January 2021, SKF South Africa , Maintenance, Test & Measurement, Calibration
The SKF Enlight Collect monitoring system combines SKF’s knowledge in machine health monitoring with LumenRadio’s patented network technology.

Read more...
Acoustic imager detects partial discharge
November 2020, Comtest , Maintenance, Test & Measurement, Calibration
Fluke’s new ii910 Precision Acoustic Imager detects corona, partial discharge and gas, steam and compressed air leaks that can hurt both production uptime and the bottom line.

Read more...