January 2021Maintenance, Test & Measurement, Calibration
Industrial, manufacturing and scientific clean rooms, by the very nature of their activities, are required to maintain extremely high levels of cleanliness. This means it is imperative to monitor differential pressure, temperature and humidity to keep compliant with local and international standards.
The Delta OHM HD50CR multi-functional clean room logger/transmitter device offers the user highly accurate clean room monitoring, along with documentation for quality purposes. Any measurement recorded out of range will trigger an alert via a predetermined list of email addresses, configured upon installation.
“The main advantage of the new monitoring device is its webserver flexibility,” said Jan Grobler, managing director of GHM Messtechnik South Africa. “Configuring the instrument is simple and can be done through any device that has been granted access to the instrument’s webserver, be it a smartphone, PC or laptop.”
The system is password protected and configuration can also take place offline by connecting the instrument to a PC with the free software installed. The instrument is pre-set to get a dynamic IP address from the network DHCP server. A static IP address can be set by using the webserver feature of the instrument or the HD35AP-S application software.
The HD50CR offers a differential pressure reading range of +/-125 Pa with an accuracy of 0,35% of measuring span. With zero drift self-calibration and a temperature drift of 0,5% of measuring span, the device’s units of measurement are Pa, mmH20, mbar, inH20 and mmHg. A variety of measuring/logging intervals are available and there is an optional T/RH probe.
The instrument will calibrate automatically at configurable intervals, the zero of the differential pressure temporarily disconnecting the pressure inputs through an internal solenoid valve.
“The HD50CR provides a perfect solution for the tracking of out-of-range values and provides evidence for any quality audit that may be conducted,” concluded Grobler. “Delta OHM has developed the instrument specifically for clean room applications, and optional modules can be provided to meet tighter regulations that may be applicable to the pharmaceutical industry. It is an excellent choice to ensure clean rooms are accurately monitored and their standards maintained.”
The HD50CR is well suited to clean room applications across all industries, but in particular to laboratories in food and pharmaceutical manufacture, as well as at chemical and petrochemical facilities.
Modernising acid cooler protection without disrupting production Omniflex Remote Monitoring Specialists
Maintenance, Test & Measurement, Calibration
Omniflex has supplied an advanced anodic protection control system to phosphate producer Foskor, replacing a legacy transformer rectifier system while maintaining uninterrupted production. The distributed PowerView CP solution provides remote monitoring and DCS integration.
Read more...Engineering partnership delivers longer life for vibrating feeders in mining
Maintenance, Test & Measurement, Calibration
: OST-Africa’s combination of VISAM vibrating motors and advanced rubber mounting technology has helped Euro Sales achieve a 30 to 40% increase in component life on vibrating feeders at several major mining operations, with zero mount failures in the first 12 months.
Read more...Why mining operations need local lightning early warning Senseca
Editor's Choice Electrical Power & Protection
Lightning can develop into a serious mining hazard before the first local strike, leaving crews little time to stop work and reach safety. Local early-warning technology can provide valuable lead time, allowing mines to connect developing storm conditions to defined trigger actions that protect people, explosives and equipment.
Read more...Sun tracking with pinpoint precision Senseca
Analytical Instrumentation & Environmental Monitoring
Senseca has introduced the SEMS-2000 solar energy measurement system, a 2-axis solar tracker with pinpoint sun-pointing accuracy that automatically monitors direct, global and diffuse irradiance for unattended outdoor solar installations.
Read more...When oil can’t take the heat
Maintenance, Test & Measurement, Calibration
Unlike the slow ageing of oxidation, thermal breakdown is the sudden chemical collapse of a lubricant under excessive heat. Steven Lumley of WearCheck explains how it happens, where it strikes, and how oil analysis detects it.
Read more...Mini data loggers for temperature and humidity monitoring
Maintenance, Test & Measurement, Calibration
Testo’s range of four compact data loggers covers temperature and humidity monitoring for storage, refrigeration and transport applications, with USB-C or Bluetooth connectivity and capacity for up to 16 000 readings.
Read more...Alternative fuels for cutting, brazing, soldering and heating
Maintenance, Test & Measurement, Calibration
Bolt and Engineering Distributors, as an authorised distributor for the Harris Products Group, is helping South African industries transition from acetylene to safer, more cost-effective alternative fuels for cutting, brazing, soldering and heating applications.
Read more...Rethinking corrosion protection in process plants Omniflex Remote Monitoring Specialists
Maintenance, Test & Measurement, Calibration
Remote monitoring is changing how cathodic and anodic protection systems are managed in process plants, giving operators continuous visibility of corrosion protection performance and enabling more proactive maintenance decisions.
Read more...Installation safety tester Vepac Electronics
Maintenance, Test & Measurement, Calibration
A combination measuring device for testing electrical installations, offering safety tests including RCD, voltage, loop, low-resistance, earth resistance and insulation checks via a 3,5-inch TFT colour display.
While every effort has been made to ensure the accuracy of the information contained herein, the publisher and its agents cannot be held responsible for any errors contained, or any loss incurred as a result. Articles published do not necessarily reflect the views of the publishers. The editor reserves the right to alter or cut copy. Articles submitted are deemed to have been cleared for publication. Advertisements and company contact details are published as provided by the advertiser. Technews Publishing (Pty) Ltd cannot be held responsible for the accuracy or veracity of supplied material.