PLCs, DCSs & Controllers


Integrated energy data management enhances PC-based control

April 2016 PLCs, DCSs & Controllers

The only way to uncover all potential energy savings is by taking a comprehensive view of the entire business – the administrative level with its offices, conference rooms, and cafeterias; the production facility level; and the individual machine and equipment levels.

To secure meaningful results, one must be able to identify all ‘energy hogs’ and make appropriate improvements in some cases, while coordinating the operation of all energy consumers, based on comprehensive and reliable energy data.

Energy-efficient Smart Factory saves costs

With such an energy measurement system, the forward-thinking company supports the creation of a ‘Smart Factory’, from the aspects that it meets the requirements of the DIN EN ISO 50001 standards as well as from an energy perspective, all with minimal effort. In addition, the integrated and, therefore, low cost energy data management system does not require large investments. Since the necessary sensors and meters can be integrated into existing buildings and machine automation systems and expanded when necessary, developing a comprehensive energy data management system step-by-step becomes relatively easy, and any investment costs quickly pay for themselves. The end user can analyse and potentially smooth out peak loads based on collected data. In addition, companies can reap clear and long-term cost benefits by consistently optimising energy usage, which is particularly important against the backdrop of almost certain future price increases.

Comprehensive and integrated energy data collection

Beckhoff PC-based control technology makes the programming of advanced measurement systems more efficient. The modular and highly scalable PC Control technology works not only for machines, but also for building automation applications with a single, universal software system that can handle all control and energy data. This makes it easy to process, combine, and correlate all relevant data, forwarding it to the energy management software. The user also benefits greatly from the flexibility and openness of PC-based control. On the one hand, all signals can be easily integrated into the control system via the modular and extremely broad I/O spectrum. On the other hand, all popular fieldbus systems and transmission standards, such as OPC UA as well as tele-control protocols, and the EtherCAT protocol are all supported and seamlessly integrated into the PC-based control system.

To maintain a highly efficient energy data management system, end users require a generalised view that can still show every detail. Controlling the company’s overall energy consumption is just as important as having precise usage data for every consumer. To accomplish this, energy usage is measured locally and with minimal wiring wherever it occurs – in each department, on each machine and on each actuator. The raw data is transmitted to the controller and TwinCAT via the fast, broadband EtherCAT network for pre-processing, scope or HMI functions. Thus, all power, heat, water, gas and compressed air consumption data is available to the energy management system via standard interfaces like OPC UA.

The benefits of a fully integrated energy data management system become especially apparent in highly complex solutions. The metering components can be added to the existing automation technology easily – even to what is already in place – without having to set up a separate metering and control system. Additionally, the seamless integration enables much faster responses to important energy-related events.

Detailed data analysis with standard control software

With the open PC-based control system, energy data is available for analysis and further processing on all software levels, not just in a higher-level energy management system. Since the TwinCAT automation software operates directly on the control level, the consumption data can be analysed directly in the control algorithms to improve plant energy efficiency. TwinCAT also supplies a wide range of advanced monitoring and analysis tools. The TwinCAT Condition Monitoring Library, as an example, features a modular toolbox of mathematical algorithms for analysing the energy status of machines and systems, with functions that cover the areas of analysis, statistics and classification.

The energy data can also be monitored with the TwinCAT software oscilloscope, which combines fast data-logging with a powerful visualisation tool. The logger can process long series in addition to very fast cycles in the millisecond range, for example, from EtherCAT monitoring I/O terminals such as the EL3773 with oversampling functionality. The results are displayed via the Scope View component, which provides an almost unlimited number of curves in high resolution over time. This enables the viewer to see, for example, whether sinusoidal voltage profiles or harmonics are present. Because of the high resolution, even short peaks become visible, which are very hard to analyse with conventional systems.

Application scenarios for better management of energy costs

Realising all potential improvements requires a comprehensive energy data management system. This enables users to integrate the collection and analysis of energy consumption data into the building automation system on the administrative level in order to optimise the consumption of power, water, gas and heat with an Embedded PC, TwinCAT and I/O terminals. In industrial environments, an industrial PC with TwinCAT in connection with EtherCAT terminals provides the ideal data management solution for evaluating cost centres such as the usage of power and compressed air. Installed within the machine, PC-based control produces and manages accurate data down to the sensor and actuator. It also provides comprehensive condition monitoring as the basis for cost-optimised preventive maintenance. This helps users generate load curves and identify peak usage periods for future load balancing. PC-based control also enables determination of each single load share, as well as the basic and average loads. Companies can also use the information to analyse the machines’ power requirements relative to each other and use the results as the basis for further improvements. Identifying ‘energy hogs’ can reduce electricity costs and make it easier to accurately allocate them to the appropriate cost centre. Detailed energy data can also be used for control purposes, for example, to make the entire production process more stable and to prevent failures.

Module-based integration of all energy data types

The PC-based control technology with its scalability and modularity provides the ideal basis for integrated and detailed energy management solutions. It also features a broad I/O system that enables data collection for all forms of energy usage within the enterprise. For example, one can collect data directly via the KL/EL3403 power measurement terminals. In addition, the EL3413 and EL3433 power measurement terminals and the EL3773 power monitoring oversampling terminal provide extended analytical functions. Consumption data for gas, water and heat, on the other hand, can be integrated indirectly into the energy data management system. The KL6781 and KL6401 Bus Terminals with M-bus and LON interface, respectively, make it easy to link popular gas, water and heat meters to the system. The typical counter pulse output can be integrated with digital input terminals.

Temperatures can be controlled directly via thermocouples or RTD resistance sensors via KL3xxx Bus Terminals and EL3xxx EtherCAT Terminals. The compressed air usage can be measured with KM37xx differential pressure measuring terminals and the locally installed EP3744 IP67 differential pressure metering EtherCAT Box, making it easy to identify energy-wasting leaks. Compressed air sensors can be indirectly integrated into the system via KL/EL3xxx analog input terminals. Sensors with IO-Link interface can also be used. Further, the EL3632 analog input terminal is suitable for condition monitoring applications in which fluctuations are recorded by means of acceleration sensors or microphones. With condition monitoring, impending failures can be recognised early on so that countermeasures can be taken before developing problems bring the application to a halt.

For more information contact Kenneth McPherson, Beckhoff Automation, +27 (0)11 795 2898, kennethm@beckhoff.com, www.beckhoff.co.za



Credit(s)



Share this article:
Share via emailShare via LinkedInPrint this page

Further reading:

A single platform for all automation functions
Beckhoff Automation Fieldbus & Industrial Networking
: The introduction of TwinCAT in 1996 marked a decisive evolutionary step for PC-based control. Today, the TwinCAT platform combines all automation functions in a strictly deterministic real-time environment, from PLC and motion control through CNC and measurement technology and beyond, to vision, robotics and pioneering AI tools.

Read more...
Advanced DCSs preserve what must not change while enabling
Schneider Electric South Africa PLCs, DCSs & Controllers
Next-generation DCSs, such as Schneider Electric’s Foxboro, are preserving the best of the old while introducing the new in a less disruptive manner.

Read more...
40 years of PC-based control
Beckhoff Automation News
When Beckhoff elevated the industrial computer to the status of a central control system four decades ago, a paradigm shift occurred.

Read more...
Dynamic control of industrial solar plants and energy storage systems
Beckhoff Automation Editor's Choice Electrical Power & Protection
Spanish Group, Power Electronics has demonstrated its comprehensive expertise in sustainable energy supply in over 3000 solar and energy storage projects with a total installed capacity of 120 GW. To control its modular systems, the company relies on open, high-performance Beckhoff control technology.

Read more...
Siemens launches new generation of logic controller
Siemens South Africa PLCs, DCSs & Controllers
Siemens has launched the latest generation of its proven intelligent logic controller, LOGO! 9. This enables simple implementation of small automation projects.

Read more...
DCS for maximum plant efficiency and reliability
ABB South Africa PLCs, DCSs & Controllers
ABB has introduced SPR2025, the latest Symphony Plus DCS package release to enable modernisation and efficient performance for the process and power industries.

Read more...
Future-proof automation
Vepac Electronics PLCs, DCSs & Controllers
The highly adaptable SALZ control system consists of open hardware, modular engineering software based on a virtualisation concept and an integrated app store.

Read more...
Robust PLC for field applications
ifm - South Africa PLCs, DCSs & Controllers
ifm is a leading suppliers of robust control systems for mobile use. Its ecomat series comprises PLCs, I/O modules and sensors that can withstand the harsh environmental influences of mobile applications.

Read more...
Modular control platform for the hydrogen industry
Beckhoff Automation Editor's Choice Electrical Power & Protection
With a seamless modular control solution from Beckhoff featuring over 500 data points and numerous ELX series terminals with intrinsically safe interfaces, Greenlight Innovation is breaking new ground in hydrogen testing.

Read more...
ABB’s new flagship DCS
ABB South Africa PLCs, DCSs & Controllers
ABB has launched the latest version of its flagship distributed control system, to help industrial operators modernise without disruption and accelerate their path toward next generation automation.

Read more...









While every effort has been made to ensure the accuracy of the information contained herein, the publisher and its agents cannot be held responsible for any errors contained, or any loss incurred as a result. Articles published do not necessarily reflect the views of the publishers. The editor reserves the right to alter or cut copy. Articles submitted are deemed to have been cleared for publication. Advertisements and company contact details are published as provided by the advertiser. Technews Publishing (Pty) Ltd cannot be held responsible for the accuracy or veracity of supplied material.




© Technews Publishing (Pty) Ltd | All Rights Reserved