Electrical Power & Protection


UPS with integrated power supply and USB interface

June 2019 Electrical Power & Protection

Supplying critical DC loads safely, increased system availability, confined spaces, and tough ambient conditions present system designers and operators with a variety of challenges. New DC UPS models from Phoenix Contact’s Trio Power series offer an interesting solution: a power supply, switching unit, and battery charger have been combined in one device.

An uninterruptible power supply, or UPS for short, is used wherever mains fluctuations or mains failures may occur. The aim is to prevent the failure of production systems caused by short-term interruptions to the power supply. In the event of prolonged mains failure, the UPS should ensure that a safe system state is entered. In addition, uncontrolled crashes on control systems such as industrial PCs should be avoided in order to prevent data loss and other damage.

Structure of a UPS system

The UPS system for DC loads generally consists of at least three components. First, the existing AC mains voltage is converted into a 24 VDC voltage by a power supply unit. This voltage now needs to be buffered. To do this, a dedicated DC UPS is used which combines two functions: firstly, it acts as a switch that connects to the supply provided by a connected energy storage device in the event of mains failure; secondly, the UPS contains a charge controller that recharges the connected energy storage device during mains operation. The third component is the energy storage device that is connected to the UPS.

Wiring effort and space required

This proven, modular structure presents advantages as well as disadvantages. The biggest drawback is the large amount of space it requires on the DIN rail. For example, a modern 24 VDC power supply unit with 5 A output power has an overall width of around 35 to 50 mm. Then you need to factor in the DC UPS for the same performance class, which has an almost identical overall width. This results in a maximum overall width of almost 100 mm. Then we have the energy storage device, which usually takes up the most space. For example, to buffer 5 A for around 20 minutes, an energy storage device with a nominal capacity of 3,4 Ah for 24 VDC is required. This has an overall width of approximately 85 mm.

Another aspect that planners need to consider is the selection of suitable power supply unit and UPS combinations. In the example above, a 5 A power supply unit and 5 A UPS were selected. But what does this actually mean? Both the UPS and the power supply unit can deliver a maximum output current of 5 A under operating conditions. So does this mean that a 5 A load can be connected and reliably supplied in both mains and battery operation? The short answer for mains operation is no.

The charging current has not been taken into consideration thus far. The UPS needs this current in addition to the load current in order to recharge the energy storage device. Assuming an additional charging current of 1.5 A, a correspondingly larger power supply unit must be selected. With some sort of reserve, e.g. to compensate for losses in the system, this would require a power supply unit with an output power of 7 A. However, the next most common size is usually 10 A. This means that a power supply unit that is twice as powerful has been selected to ensure a load current of just 5 A. This results in higher initial costs and takes up even more space.

However, the modular structure does have advantages. With this option, it is easy to distinguish between critical and non-critical loads. Critical loads must continue to be supplied in the event of mains failure, such as in the case of a controller. Non-critical loads, on the other hand, do not have to be supplied in the event of mains failure. This is why uncritical consumers are connected directly to the power supply unit output, while the relevant consumers are connected to the UPS output first.

Practical example for an elevator controller

In numerous applications, a complete structure such as a control cabinet needs to be supplied. This is where the problem of limited space really becomes apparent. One example for the use of a UPS is the supply of an elevator controller. Here, in the event of mains failure, the operator or even the emergency services must be notified by means of remote signalling. The power consumption of the required consumers is a maximum of 4 A, and the required buffer time exceeds 5 minutes. Furthermore, special normative requirements also apply to these types of applications – the connected energy storage device must be actively monitored, for example.

For these types of application, Phoenix Contact offers a practical solution in the form of second generation Trio Power uninterruptible power supplies. Combining a power supply unit with wide-range input and integrated UPS, the devices are particularly suitable for applications where space is limited and all connected loads need to be buffered.

In the elevator application, an output current of 4 A is required. The ideal solution here is the Trio Power UPS with 5 A nominal output, which has a 20% reserve to support extension. With an overall width of just 60 mm, the compact device also provides a maximum charging current of

1,5 A internally, in addition to the load current. The user can therefore be confident that the 5 A device has sufficient reserves to charge the energy storage device. In addition, they can select the device that best suits the load requirements of their application. No further consideration needs to be given to the charging current.

In order to achieve the required buffer time, an energy storage device with 1,3 Ah simply needs to be connected to the UPS. Active battery monitoring can also be easily implemented using UPS devices from the Trio Power series. They feature an alarm signal contact and an LED indicator, which are activated, for example, if the maximum permissible recharging time has been exceeded and the battery is potentially faulty. In addition to error evaluation via signal contacts, a PC can also be connected via USB. The UPS system can then be conveniently monitored via the UPS-Cong software, which is available free of charge.

Compact devices with useful functions

The new UPS devices from the Trio series showcase their advantages in confined spaces. The combined power supply unit and UPS not only save space, but simplify planning. Despite their compact design, the devices deliver a high level of performance and are tailored to the requirements of numerous fields of application.

For more information contact Sheree Britz, Phoenix Contact, +27 11 801 8200, [email protected], www.phoenixcontact.co.za



Credit(s)



Share this article:
Share via emailShare via LinkedInPrint this page

Further reading:

Energy audits pave the pathway to sustainability and savings
Schneider Electric South Africa Electrical Power & Protection
Energy audits serve as essential tools for businesses looking to reduce costs and meet environmental targets. By analysing energy consumption across systems such as lighting, HVAC, ICT and water infrastructure, audits identify inefficiencies and quantify carbon footprints, enabling data-driven decisions for operational and financial optimisation.

Read more...
Passive fire protection for lithium-ion battery risks
Electrical Power & Protection
In response to the growing threat posed by lithium-ion (Li-ion) battery fires, a breakthrough passive fire protection solution is now available in South Africa.

Read more...
Schneider Electric unveils new range of circuit breakers
Schneider Electric South Africa Electrical Power & Protection
Schneider Electric has launched its new MasterPacT MTZ Active range of circuit breakers in South Africa. This is a revolutionary new circuit breaker designed to set new benchmarks for safety, efficiency and sustainability while ensuring business continuity.

Read more...
Reliable power for demanding applications
Conical Technologies Electrical Power & Protection
In modern industrial automation, reliability, efficiency and compact design are critical when selecting power supplies. The Mibbo Power MTR480 three-phase DIN-rail power supply is engineered to meet these exacting requirements.

Read more...
Managing dynamic steam plant operation on a multi-user site
Electrical Power & Protection
Managing a dynamic steam plant operation featuring multiple users requires strong technical skills, good communication and close attention to optimising results. AES’s remote monitoring system gathers steam generation plant data and records critical operational monitoring parameters.

Read more...
South Africa’s journey to smart, greener transport
Schneider Electric South Africa Electrical Power & Protection
The good news is that there are some truly feasible solutions that can assist in overcoming some of South Africa’s most pertinent transport electrification challenges.

Read more...
Precise, fast universal power and net quality meter
Vepac Electronics Electrical Power & Protection
The eCap from Vepac measures voltages, currents, power, power factor, energy, frequency and total harmonic distortion (THD) with all harmonics (up to 20th), and allows fully galvanically isolated transmission via the integrated Modbus RTU/RS485 interface.

Read more...
Novel stacked capacitors
Electrical Power & Protection
KYOCERA AVXhas released the new DSCC 25007 Mini BME stacks. These are miniature, high-CV stacked X7R capacitors equipped with base metal electrodes (BME) and subjected to 100% Group A testing.

Read more...
Circuit breakers for reliable, compliant protection
Electrical Power & Protection
Legrand’s low-voltage power distribution portfolio encompasses the DX3 range of miniature circuit breakers, designed to deliver dependable protection in industrial installations.

Read more...
Grid to backup power in zero seconds
Electrical Power & Protection
South Ocean Electric Wire has completed a solar installation that marks a global first: a seamless switch from grid to backup power in zero seconds.

Read more...









While every effort has been made to ensure the accuracy of the information contained herein, the publisher and its agents cannot be held responsible for any errors contained, or any loss incurred as a result. Articles published do not necessarily reflect the views of the publishers. The editor reserves the right to alter or cut copy. Articles submitted are deemed to have been cleared for publication. Advertisements and company contact details are published as provided by the advertiser. Technews Publishing (Pty) Ltd cannot be held responsible for the accuracy or veracity of supplied material.