IBG
DirectLogic Automation

75 Marinda Avenue, Clubview East, Centurion

tel:  
+27 12 654 6212
cell:  
+27 12 660 1427
email:  
[email protected]
url:  
www.directlogic.co.za

Core business offering: South African supplier of a wide range of PLC, HMI and networking solutions, process sensors and field mounted electrical and process control instrumentation, throughout Africa and the Emirates.


Grey, Jeni
Admin Manager
[email protected]
Ilsley, Sherrill
International Accounts
[email protected]
Ilsley, Winston
Owner
[email protected]
Malangu, Joanna
Housekeeper
Mtshweni, Jacob
Repairs
[email protected]
Wiese, Pieter
Product Sales
[email protected]
BRX
(Sole Agency)
Click
(Sole Agency)
Do More
(Sole Agency)
Imputel Technologies
(Sole Agency)
Koyo (PLCs, HMIs)
(Sole Agency)
Maple Systems
(Shared Agency)
Productivity
(Sole Agency)
Prosense (field mounted sensors)
(Sole Agency)
Protech Systems
(Sole Agency)
StrideLinx
(Sole Agency)
WEG
(Sub Agency)
Weintek
(Shared Agency)
Section - Computers & Software
-Computers
- desktop
- servers
- workstations
-Industrial computers
- Board level
- Compact, embeddable (PC/104, PCI, ISA bus) modules
- Explosion protected
- Flat-panel
- Pentium architecture
- PLC plug-in
- Rackmount
- RISC architecture
- Wall mounted, embeddable
- x86
-Input devices
- Keyboard/video/mouse (KVM) extenders & switches
- Keyboards
- Mice, trackerballs
- Network interfaces (see I/O table)
- Touchscreens
-PC function cards, modules
- Graphics accelerator
- IEEE-488 (HPIB)
- Mass storage magnetic
- Memory, solid state disk
-Peripherals
- CRT/LCD terminals
- Monitors/display systems
-Electrical design
-Instrumentation design
-Motion control system design
-Communication medium
- Copper
- Optical fibre
- Radio
-Communication standard
- Ethernet/IP
- Modbus
- RS232/485/422
-I/O blocks/modules
-Mounting methods
- DIN rail
- Panel/rack mount modules
- Plug in cards
-Operating features
- Diagnostic capability
- High temperature
- Intrinsically safe
-Signal modules
- Analog
- Digital
- Mixed
-Applications
- Alarm management
- Asset management
- Calibration management
- Data acquisition, analysis
- Direct control
- Drivers
- DSP (digital signal processing) software
- Dynamic link to libraries (DLL)
- Link to Windows databases
- Manufacturing execution systems (MES)
- Operator interface
- Programming languages
- Soft PLC
- SPC/SQC
- System simulation/PID tuning
-Datasharing
- DDE
- OLE
- OPC clients
- OPC servers
-Language
- C, Pascal, etc
- MS Visual Basic
- OOP (e.g. Visual C++)
- PLC languages
- Provides OCXs
-Network communications
- IPX/SPX
- TCP/IP
-Operating Systems
- .Net
-Operating systems
- Linux
- Windows 2000
- Windows 95/98
- Windows CE
- Windows NT
- Windows XP
Section - Data Acquisition & Remote Control
-Barcode systems
- Handheld
-Ethernet-based systems
-Machine health monitoring
-PC based data acquisition
- A-D conversion boards
- automatic data acquisition
- data acquisition cards
- distributed data acquisition
- intranet system
- presentation/analysis software
-Recorders
- events
-Alarms
-Integration into MES and ERP systems
-Number of I/O points
- 0-1024
- 0-32
- 0-512
- 0-64k
- Unlimited
-Number of PLC or I/O drivers
- 0-16
- 16-64
- 64-640
-Operating system
- .Net
- Linux
- Windows 2000
- Windows 95/98
- Windows NT
-Reports
-Standalone version available
-Cable telemetry
- copper wire
- Ethernet LAN
-Radio telemetry
-Remote sensing & control
- cable link
- cellular
- from rotating shaft
- infrared (IR)
- radio link
Section - Miscellaneous Hardware
-DC-DC converters
-Instrument power supplies
-Mains AC-DC converters
-Mains/power conditioners
-Heavy duty power switching
-Reed relays
- Dry-contact
- Mercury-wetted
-Relays
- DIN-rail mount
- General purpose, control
- Plug-in
- Solid state (photo MOS)
- Solid state (zero-crossing)
- Time delay
-Switches
- Cam-operated
- Foot-operated
- Intrinsically safe
- Key-lock
- Magnetic
- Membrane, custom
- Pushbutton-control
- Rocker
- Rotary selector
-Emergency stop switches
-Fuses
- Fast-acting
- Normal
- Slow-blow
-Optical isolators
-Protection relays
- Over/under voltage
- Over-current
- Phase balance
- Phase sequence
- Pump protection
- Thermal overload, motor protection
-Safety limit switches
-DIN rail-mount
-I/O system
-Patching/cross-connection
-PLC interface
-Pluggable terminal blocks
-Screwed clamp
-Tab connector blocks (panel)
-Thermocouple
Section - Networks for Communication & Control
-4-20mA analog loop
-DCS Data Highway
-DeviceNet
-Ethernet
-Modbus
-Network analysers
- Modbus
- PLC Data Highway
- RS232/422/485
-PLC Data Highway
-Remote I/O
-RS232/422/485
-Universal Serial Bus (USB)
-Wireless (for industrial application only)
Section - Process Control & Manufacturing Technologies
-Communications
- Fieldbus
- Proprietary
- RS232
- RS422/RS485
-Functionality
- Adaptive gain
- Auto/self tuning
- Cascade control
- Logic
- Maths/calculations
- Pattern/profile
- PID/PD
- Ratio control
- Scaling of I/O
-Inputs
- 0/4-20mA
- mV/V
- RTD
- Thermocouple
-Number of loops
- >16
- 1-16
-Outputs
- 0/4-20 mA
- 0-5V
- mA/mV
- Pulse
- Relay contact
-Visual display
-AC control
- Inverters - 1 phase AC
- Inverters - 3 phase AC
- Soft starter
-AC motors
- Induction motors - geared motor units
- Induction motors - over 10kW
- Induction motors - up to 10kW
- Synchronous motors - brushless
- Synchronous motors - permanent magnet
-DC control
- 4-quadrant control
- Speed control
-DC motors
- Brushless
- Geared
- Permanent magnet
- Wound field
-Flowmeters (type)
- Differential pressure (DP)
- Magnetic/electromagnetic
-Potable water meters
-Regulators
-Switches
-Totalisers and correlators
-Fire detection & extinguishing equipment
-Gas detection
-Accessories
-Accumulators
-Actuators
-Couplings
-Hoses & fittings
-Motors
-Industrial IT & networking
-Smart sensors
-Capacitive & conductive
-Fibre-optic
-Float-operated
-Pressure/hydrostatic
-Tank gauging
-Thermistor / thermal
-Ultrasonic
-Alarm indicators
-Analog panel meters
-Annunciator panels
-Digital panel meters
-Digital process indicators
-Displays
- Bar graphs
- Characters
- CRT
- Display wall (control room)
- LCD, flat-panel
- Programmable message
- Touchscreens
-HMI
-Keyboards
- Custom
- Desktop
- Flat-panel
- Rackmount
- Sealed
-Keypads
- Harsh-environment
- Key-switch
- Membrane
- Outdoor (weather-proof)
-Analog I/O
- 1-16
- 17-64
- 65-256
- 257-512
- more than 512
-Digital I/O
- 1-16
- 17-64
- 65-256
- 257-512
- more than 512
-Display
-Multiprocessor
-Networking organisation
- Host-to-PLC link
- PLC-to-PLC
- Remote I/O
-Networking
- 20 mA loop
- Ethernet
- Fieldbus
- PLC-to-PLC
- Proprietary data bus
- Remote I/O
- RS232, RS422, RS485
-Operator interface panel
-PACs - Programmable Automation Controllers
-Programming
- Diagnostic software
- Documenting software
- Function block diagram
- High level (C, Basic, etc.)
- IEC 1131
- Ladder diagram (relay logic)
- Logic diagram
- Sequential function chart
-Scan rate less than 1µs per step
-Scan rate less than 1ms per step
-Scan rate more than 1ms per step
-Actuators
- Linear
- Rotary
-Controllers/logic devices
-Pneumatic conveying systems
-Pressure/vacuum switches
-Tubes & fittings
-Valves
- Check
- Flow
- Gauge
- Isolation
- Manifolds
- Pressure
- Servo
-Computer interfaces
-Control transducers
- Displacement/position transducers
- Synchros & resolvers
- Tacho generators
- Tilt transducers
-Gearboxes
-Impactors - magnetic
-Programmable motion control systems
- Custom system design
- Hydraulic drive systems
- Pneumatic drive systems
- Servo systems
- Stepper systems
-Rotary encoders
-Servo motors
- Brushless DC motors
- Cage rotor induction motors
- DC motors
- Geared motor units
- Linear motors
- Stepper motors
- Synchro motors
-Differential pressure transducers
-Pressure gauges/indicators
-Pressure switches
-Pressure-electrical transducers
-Capacitive
-Inductive
-Infrared
-Limit switch
-Machine guard
-Magnetic
-Photoelectric
-Ultrasonic
-Current
-Displacement
-Fibre-optic
-Flow
-Gas
-Humidity
-Interface in solids/liquids
-Level
-Converters
- A-D
- D-A
- I-P, P-I
- mV/current
- Power (VAR, F, kWh, etc.)
-IR non-contact
-Panel-mount indicators
-RTDs (Pt 100, Ni)
-Temperature indicating paints/labels
-Temperature switches
-Thermistors (PTC, NTC)
-Thermocouple extension cables
-Thermocouple reference units
-Thermocouples (Type S, T, etc)
-Thermowells
-Timers
- Analog
- Digital
- Panel mount
-Conductivity
-Control signal
-Differential pressure
-Flow
-Level
-Pneumatic
-Pressure
-Temperature
-Universal, programmable
Section - Services & Systems
-Programmers
- PLC
- scada
-System integration/consulting
- Electrical
- Factory automation
- Information systems
- Process control
- Scada/DCS/PLC
- Telemetry
News from DirectLogic Automation:
DirectLogic Automation appointed distributor for Automationdirect.com
October 2012, News, DirectLogic Automation

Atlanta-based Automationdirect.com, the current global distributor of the Koyo range of DirectLogic PLCs, has appointed DirectLogic Automation (DLA) as its distributor for Africa and the Middle East. ...

Do-more H2 series PLC CPUs from DirectLogic Automation
October 2012, PLCs, DCSs & Controllers, DirectLogic Automation

Leverage the DL205 I/O modules and base units to create an incredibly powerful PLC.

AutomationDirect introduces programmable automation controller
October 2011, PLCs, DCSs & Controllers, DirectLogic Automation

New Productivity 3000 PAC drives efficiency

DirectLogic awarded new dealership
March 2008, News, DirectLogic Automation

In a bid to supplement its current range of ICT solutions, DirectLogic Automation has secured a distribution agreement with Protech Systems. Established in 1980, Protech Systems specialises in the design ...

Industry news:
Loop signature 22: How cyclical disturbances affect a control loop
April 2024, Editor's Choice, Michael Brown Control Engineering

When tuning noisy loops, we recommend in our courses that one should eliminate the noise by editing it out, so the tuning will be done only on the true process response, free of any noise. The controller is controlling the process, and is not controlling the noise.

RS Group chooses Siemens simulation technology for DesignSpark
April 2024, IT in Manufacturing, Siemens South Africa

Siemens Digital Industries Software announced that the RS Group has selected Siemens as its strategic electronic design automation provider for its new, cloud native, DesignSpark Circuit Simulator tool, which empowers users to streamline the design process.

Chain hoist friction clutch tester
April 2024, Motion Control & Drives, WIKA Instruments

WIKA’s FRKPS chain hoist test set is a reliable and efficient way to test the friction clutch on your chain hoist.

Monitoring the voltage drop in cables
April 2024, Electrical Power & Protection, Turck Banner Southern Africa

With its new M12Plus connectors, Turck Banner is directly shifting the condition monitoring of cables subject to severe stress to the connection technology. The connectors, which come with voltage and current monitoring and a Bluetooth chip, enable measured voltage and current values to be sent wirelessly to a controller.

Seamless automation system upgrade
April 2024, Industrial Computer Hardware, ABB South Africa

ABB has launched the ABB Ability Symphony Plus SDe Series, a portfolio of hardware products that help modernise existing process control system installations with minimal risk and disruption to plant operations

visit www.instrumentation.co.za

         
 
 
             
   
     
Copyright © Technews Publishing (Pty) Ltd. All rights reserved.