Sensors & Transducers


Humidity measurement in poultry farms

August 2017 Sensors & Transducers

Incubation

Eggs are kept in the incubator for a total of 18 days. There are two schools of thought on the correct humidity level to use during this stage. The most popular condition for incubating the eggs is 53% RH @ 37°C. Towards the end of the incubation period, the eggs will start to release CO2, which builds up in the incubator. Valves open to vent this excess and keep the CO2 close to atmospheric levels, which has the side effect of venting water vapour and reducing the humidity level inside, therefore humidifiers are used to compensate for this and keep the level around the required 53%.

Some customers see better uniformity of chicks when they are incubated in a higher humidity initially – 60% or higher in some instances (still at 37°C). They still vent the excess CO2 towards the end of the incubation cycle, but do not replace the water vapour lost at this stage.

If the egg tray is not completely full, then the level of humidification will need to be higher to maintain the required 53% level.

Measurement

The measurement in this environment is fairly clean and after 18 days the eggs are moved to another room. Cleaning methods will vary from site to site, but typically are less invasive. The sensors here typically will have a longer lifetime than those in other areas of the farm.

Hatching

Following the 18 days of incubation, the eggs are moved to the hatcher, where they spend a total of three days. This cycle also begins with a condition of 53% RH @ 37°C. As soon as the chicks begin to hatch, the humidity level naturally increases, up to around 80%. This higher humidity actually assists the other chicks by making the shells slightly softer, allowing them to hatch more easily.

As the chicks hatch, CO2 levels also increase, so ventilation and humidification starts. Once all the chicks are hatched, humidity will be maintained around 60%.

As in the incubator, if the egg tray is not completely full then the level of humidification will need to be higher to maintain the required 53% level.

Measurement

This is a more demanding measurement as the hatching is a messy process. After the chicks are removed, the room will be decontaminated by pressure-washing with a mixture of water and disinfectant. It is this stage which is particularly damaging to the sensor, which should ideally be removed, or at least covered up while this cleaning process is taking place.

Adult chickens

Normal body temperature for chickens is 41,5°C, however this will fluctuate depending on environmental temperature. Maintaining a constant body temperature is not a problem when air temperature is at least 10-15 degrees less than body temperature, but air movement is critical. A bird can only give off heat to its environment if the temperature of that environment is cooler than the bird. If heat produced by the birds is not moved away from them and out of the poultry house quickly, it will be more difficult for them to avoid heat stress.

The ambient temperature should be maintained at <around25°C to avoid stressing the chickens, but more importantly, the environmental temperature should be kept as stable as possible. Fluctuations in the temperature, especially in combination with high relative humidity, will be more stressful to the birds than a high ambient temperature alone.

Measurement

This is the toughest measurement of the three as any sensors installed into the living environment or on the air outlets will experience drift over time, due to the NH3 content in the air. There is also a significant amount of dust, which can cause premature failure on sensors with inadequate filtration.

By far the best location for controlling this environment is on the fresh air inlet.

Cleaning will also periodically take place in this environment, and the same precautions should be followed as in the hatchery, the sensors should be either removed or covered to prevent irreversible damage.

Michell’s HydroSmart HS3 probe

The probe is proven to be a suitable product for withstanding the conditions described above, if the following precautions are adhered to:

• Probes should be mounted in a vertical orientation.

• Probes should always be covered, or ideally removed completely, during decontamination/cleaning cycles.

• Probes should never be cleaned with any kind of solvent, detergent or pressurised water, they should just be wiped down with a damp cloth.

For more information contact Instrotech, +27 (0)10 595 1831, sales@instrotech.co.za, www.instrotech.co.za



Credit(s)



Share this article:
Share via emailShare via LinkedInPrint this page

Further reading:

Efficiency and precision with IO-Link sensors
RS South Africa Sensors & Transducers
RS South Africa has its own brand known as RS PRO, which offers a choice of over 88 000 products across all industries and technologies. The guaranteed quality and breadth of this range make RS PRO the smart choice for your business.

Read more...
Smart alternative for float switches
ifm - South Africa Sensors & Transducers
With the LI level sensor, you can reliably detect leakages and point levels on a permanent basis. The capacitive measuring system has no moving parts. Malfunction or maintenance issues due to deposits on the mechanical parts are therefore eliminated.

Read more...
Optical fork sensor series
Gail Norton Instrumentation Sensors & Transducers
The OFS series consists of self-contained optical fork sensors that are housed in a durable, U-shaped aluminum housing, which operates in through-beam mode.

Read more...
In-line process transmitter to optimise sterile processes
WIKA Instruments Sensors & Transducers
The new model DMSU22SA in-line process transmitter from WIKA helps to optimise sterile processes in the pharmaceutical and food industries, with less energy consumption, less cleaning effort ,and more safety.

Read more...
Automated clean-in-place
Endress+Hauser South Africa Sensors & Transducers
A clean-in-place (CIP) process is integral to a food and beverage producer’s responsibility to deliver safe, high-quality products to consumers. However, as industries worldwide shift focus towards sustainability, CIP procedures face new challenges.

Read more...
Signal conditioning is the protective armour between plant and field
Omniflex Remote Monitoring Specialists Sensors & Transducers
Measurement and control of physical properties are the foundation of all critical industrial technologies. Ian Loudon, international sales and marketing manager at remote monitoring specialist, Omniflex explains the challenges of industrial signal conditioning and the importance of safety engineering.

Read more...
Wind turbines with smart sensors
Instrotech Motion Control & Drives
The wind’s usable kinetic energy increases with the wind speed. Wind turbines, therefore, use kinetic energy to generate torque and then rotational movement. The rotor, consisting of three rotor blades, ...

Read more...
Precise detection of complex rotational movements
Beckhoff Automation Sensors & Transducers
The EP3751-0260 EtherCAT Box module by Beckhoff connects an acceleration sensor with an inertial measurement unit - a gyroscope. This provides accurate detection of acceleration and rotational motion in addition to shock, vibration and tilt measurement, both as preprocessed values and as raw sensor data.

Read more...
Infrared camera for condition monitoring and early fire detection
Instrotech Temperature Measurement
The Optris PI 640i thermal imager is the smallest measuring VGA infrared camera, with a body-sized volume of 45 x 56 x 90 mm, and weighing only 269 to 340 g, depending on the lens. It counts among the most compact thermal imaging cameras on the market.

Read more...
OEM pressure sensor for mobile working machines
WIKA Instruments Sensors & Transducers
The MH-4-CAN, based on the MH-4, is a powerful, reliable and extremely resilient pressure sensor for mobile working machines.

Read more...