Analytical Instrumentation & Environmental Monitoring


pH/ORP measurement for reverse osmosis

May 2017 Analytical Instrumentation & Environmental Monitoring

Processes requiring pure water must continually replace that which is consumed. Sources of replacement water are usually local supplies from a river or dam, and therefore require pre-treatment and purification before it can be used in the process.

After preliminary purification which may include filtration, clarification and softening, further downstream, a two-pass reverse osmosis system and demineralization operations are typically employed for final purification. Osmosis is the natural tendency of a fluid, usually water, to pass through a semi-permeable membrane from a less concentrated solution into a more concentrated one, thus equalising the concentrations on each side of the membrane.

Reverse osmosis

In reverse osmosis (RO), pressure must be exerted on the side with the concentrated solution to force the water molecules across the semi-permeable membrane to the fresh (pure) water side. The semi-permeable membrane inhibits the majority of dissolved impurities from passing through to the pure water. The amount of impurities carried over depends on the type and condition of the membrane (i.e. age, cleanliness) and the amount of pressure applied (energy) to the process. Not all the feed water passes through the membrane. Some is diverted to flow over them to cleanse away the rejected impurities in a cross-flow filtration mode.

The RO system produces one purified water stream called permeate and a second stream called concentrate, brine, or reject. Feed water enters the machine at fairly low pressure and flows through pre-filters to remove suspended particles, such as silt. Pre-filters are typically a replaceable cartridge type which provides a cost-effective method for keeping the membrane clean. Typical life expectancy for these membranes is approximately three years.

RO systems are designed for automatic operation and require routine preventative and corrective maintenance. Common problems include membrane fouling and the use of improper flow rates. The result is reduced throughput capacity and shortened runs. Membranes can fail altogether, resulting in excessive demand on downstream purification systems and poor quality product water. Both pH and conductivity measurements are used to safeguard the successful operation of an RO system.

Some types of RO membranes are sensitive to feed water pH and can become damaged if it is outside the recommended range of 5 to 8. A pH sensor upstream of the membrane can provide a feedback signal to control dosing of acidic or basic reagent to maintain the pH within acceptable limits.

Conductivity measurements are used at both the inlet and outlet of the RO unit to determine whether the total dissolved solids are being filtered effectively.

General applications

Reverse osmosis systems can remove up to 100% of suspended solids and approximately 90% of dissolved solids, dissolved silica, alkalinity and hardness.

A common use for RO is for purifying water, removing salts and other impurities to improve the colour, taste and other properties. It is regularly used for commercial and residential water filtration and is also one of the methods used for desalinisation of seawater.

RO systems are capable of rejecting bacteria, salts, sugars, proteins, particles, dyes, and other constituents which have a molecular weight of greater than 150-250 Daltons.

The separation of ions with reverse osmosis is aided by charged particles. This means any dissolved ions which carry a charge, such as salts, are more likely to be rejected by the membrane than those that are not charged, such as organics. The larger the charge and the larger the particle, the more likely it will be rejected.

The majority of RO membranes are negatively charged when they are operated within the pH levels most commonly encountered in water applications.

Pure water applications

A two-pass RO system is typically installed upstream of the demineraliser. Its performance is pH dependent with the second-pass section most dramatically affected. A Yokogawa PH450 together with Yokogawa 4 in 1 pH probe is used to ensure that the correct pH is passed through. The PH450 is a full PID controller that can control the correct amount of reagent chemical feed into the process. While these changes are not significant in the majority of applications, variations become crucial to the success of high-purity water processing.

In addition, the effect of minor feedwater constituents, such as alkalinity and ammonia also play a role in achieving high-purity permeate. The overall efficiency of dissolved solids removal is usually determined utilising a pair of conductivity measurements, one at the inlet (cell 1) and one at the outlet (cell 2). This is referred to as % rejection and calculated by the formula: % rejection = [1-(cell2)/ (cell 1)] x 100.

For example if the inlet water had 200 ppm of dissolved solids and the outlet water had 10 ppm, the efficiency would be 95% rejection rate. A typical range for this type of application is 80% – 100% rejection.

For this analysis, two SC4A conductivity probes are connected to one Yokogawa Flxa21 transmitter. The output is configured as the % rejection.

As a final conductivity measurement, another FLXA21 can be utilised after the second stage. This is often used to determine the absolute quality of the outlet water.

Ammonia also affects the production of high purity water and may be present due to municipal chlorination of feed water or from organic contamination. Ammonia (NH3) will pass through the membrane system in either the molecular or ionic (NH4+) form.

Ammonium hydroxide is less conductive than ammonium carbonate [(NH4)2CO3] so it is not uncommon to find off-line samples or storage tank water with conductivity higher than that of on-line readings.

The pH values will be lower. This shift in pH is due to absorption of CO2 from the air and the formation of carbonic acid in the water. Without the presence of ammonia, this type of contamination of high-purity water with CO2 would generate higher conductivity as well as the reduced pH.

For more information contact Christie Cronje, Yokogawa South Africa, +27 (0)11 831 6300, christie.cronje@za.yokogawa.com, www.yokogawa.com/za



Credit(s)



Share this article:
Share via emailShare via LinkedInPrint this page

Further reading:

Keeping an eye on invisible radiation
Omniflex Remote Monitoring Specialists Analytical Instrumentation & Environmental Monitoring
At its peak in 1994, the energy generation capacity of the UK’s nuclear power stations was 12,7 GW across 16 plants. In 2024, the capacity has fallen to around 5 GW, and the number of stations is down to nine. However, this is far from the end of the story as spent nuclear fuel remains radioactive for centuries, and requires rigorous safety processes to safeguard against leaks.

Read more...
Effective dust control in sugar processing
Analytical Instrumentation & Environmental Monitoring
BLT WORLD specialists work in conjunction with the global ScrapeTec team to offer dependable solutions for specific problems at the transfer points of conveyor systems in many industries where dust and material spillage are concerns, including the sugar sector.

Read more...
A benchmark for lubricant reliability in mining
Analytical Instrumentation & Environmental Monitoring
According to Craig FitzGerald from ISO-Reliability Partners, mines can save R500 000 or more on their yearly mill cleaning costs, while electricity consumption can be reduced by up to 12%, and lubricant consumption lowered up by up to 60% when using Bel-Ray Clear Gear lubricant.

Read more...
Safeguarding precision in industrial radiometric measurements
Mecosa Analytical Instrumentation & Environmental Monitoring
In the complex landscape of industrial plant operations, precision is paramount, especially when it comes to weld inspections to test for structural integrity of pipes. Berthold has the ideal answer to this challenge – X-Ray Interference Protection.

Read more...
New indoor air quality monitor
RS South Africa Analytical Instrumentation & Environmental Monitoring
RS South Africa has available a new indoor air quality (IAQ) monitor that provides continuous, easy-to-read, and accurate real-time monitoring of air quality in indoor environments.

Read more...
A quick guide to disinfection
Endress+Hauser South Africa Analytical Instrumentation & Environmental Monitoring
The distribution system in a drinking water network provides a reliable supply of high-quality water to consumers. Endress+Hauser’s range of robust, low-maintenance sensors are ideal for monitoring disinfectant levels in the water.

Read more...
Multi-parameter measuring system for water quality monitoring
KROHNE Analytical Instrumentation & Environmental Monitoring
Monitoring different parameters in water treatment processes can lead to a situation where different measuring points are scattered across the plant.

Read more...
Optimising energy consumption in the chemical industry
Anton Paar Analytical Instrumentation & Environmental Monitoring
To optimise energy consumption and save valuable resources on chemical process plants, operators have to continuously measure parameters such as concentration, raw density, sound velocity and refractive index. With Anton Paar’s wide product range, the process application team has many options for cutting-edge laboratory measurement technologies, and can develop tailor-made mathematical models for every application.

Read more...
Smart sensor for condition monitoring
Yokogawa South Africa Sensors & Transducers
Yokogawa has developed a compact, intelligent, low-power battery-operated wireless sensor, the LoRaWAN, that can be deployed to perform vibrational condition monitoring in the field.

Read more...
Sustainability through optimisation
Analytical Instrumentation & Environmental Monitoring
Understanding and controlling the entire process chain is crucial for prolonged maintenance and support. Through optimisation we directly increase product quality and profit margin. However an often ...

Read more...