Fieldbus & Industrial Networking


Five future challenges for ­industrial Ethernet switches

December 2016 Fieldbus & Industrial Networking

The industry-wide acceptance of industrial Ethernet technology can pose hidden threats to industrial network availability resulting from the inherent challenges found at field-level environments. This paper discusses how future industrial Ethernet networks can introduce new challenges for industrial switch reliability, bandwidth availability, switch security, switch manageability and network redundancy.

Switches must resist field-level environmental impact

If industrial Ethernet technology is increasingly being deployed at remote field locations, industrial Ethernet switch reliability will need to be robust enough to handle harsh field site conditions, which can include high-voltage transients, severe shock and vibration, and extremely high temperatures.

High-voltage transients can result from ESD, surge, burst, EFT, and lightning strikes. Industrial switches should be capable of repelling high-voltage transients with high electromagnetic protection.

Electrostatic discharge (ESD)

ESD is the sudden transfer of static electricity between two objects with different electrical potentials. For example, factory workers wearing rubber boots and gloves can easily accumulate high levels of static electricity. Physical contact with switch devices can discharge several kilovolts (kV) of static electricity and permanently damage internal circuitry.

Surge/burst/electrical fast transients (EFT)

Switching disturbances and short circuits can inject high-level voltage spikes to cause serious damage to switch devices. Industrial high-powered equipment/machinery can require large amounts of energy to switch on and turn off components such as motors and hydraulic systems. This switching can abruptly generate high quantities of power flow, disrupting the steady voltage flow in the electrical system, which can be severe enough to instantly damage, or gradually degrade, device system circuitry.

Electrical field emissions (radiated)

Not to be confused with conducted electromagnetic emissions, electrical field emissions can affect almost every device. Electromagnetic radiation can be emitted by one device to generate RF currents in surrounding devices, causing electromagnetic disturbances and even possibly damaging a device. RF shielding, such as metallic device housings, can effectively repel electrical field emissions.

Shock and vibration can disconnect wires for communication, power and relay output. Longterm exposure to shock and vibration can eventually result in electrical shorts, broken solder joints, loose PCB components, PCB delamination, and cracked device housings. Shock and vibration can also disable a switch by shaking loose wires for power, data, and redundancy. Remote field locations with moving heavy machinery or high vehicular traffic will require industrial switches with high shock and vibration resistance.

Extreme temperatures can quickly deteriorate device internal circuitry. Extreme outdoor temperatures can reach below freezing at night, and rise to an excess of 50°C during the day. Temperatures inside roadside cabinets can even reach extreme temperatures of over 60°C. Thermal stress/cycling will cause PCBs to expand and contract, which can also cause broken solder joints and PCB delamination. Remote onsite locations will likely not have air conditioning, high temperature tolerance with optimal heat dissipation is necessary to prolong switch lifetime.

Bandwidth availability must be highly scalable

As remote field applications converge onto one single network, especially for video and other bandwidth-hungry applications, bandwidth and network availability will be critical factors to consider during network design. While a 100-megabit network will generally be enough for a network of 10 to 15 cameras (each using roughly 3 Mbps of bandwidth at 720p resolution), a large scale surveillance network with more than 30 cameras will likely require a gigabit backbone for video transmission. Industrial switches should be capable of gigabit speeds to prevent network congestion and provide optional fibre interfaces to allow long-distance data transmission from field sites back to the control room.

Network redundancy must provide millisecond-level recovery

Network redundancy will also be crucial in maintaining high network availability. RSTP is acceptable in an enterprise network where a few seconds of network delay is acceptable. But in an industrial control network, one second of network interruption can severely impact production process and even jeopardise the safety of onsite personnel. Many proprietary ring technologies for redundancy will claim sub-50 millisecond recovery times. However, as the number of switches increases, recovery time can take up to hundreds of milliseconds. Turbo Ring is a field-proven redundancy technology that has been proven to provide sub-20 millisecond network recovery, even when tested with a ring of 250 switches. As field-level applications are aggregated onto the network, network redundancy becomes even more critical in ensuring network resilience.

Industrial networks must be secure to protect critical systems

Security vulnerabilities and loopholes of most industrial networks are, unfortunately, discovered only after a security breach has occurred. Existing systems were previously isolated and inaccessible via a remote connection. However, the integration of these existing systems with IT data networks will undoubtedly present inherent network risks and vulnerabilities. With the rapid growth of industrial Ethernet nodes deployed at field level, possible sensitive/confidential information will need to be protected with network-level authentication, such as with VPN (virtual private network) and firewalls, to deny unauthorised access to the network.

Switch-level security measures, such as Radius and TACACS+ for user access authentication, IEEE 802.1X for port-based access, and HTTPS, SSH, SNMPv3 for data encryption, are vital in denying unauthorised access to ensure a healthy network state. Role-based account management is also an important security measure, which can be used to grant switch access to different authorised users using multi-level access permissions.

Switch manageability must be designed for easy operation

Switch manageability is an important aspect of maintaining large-scale networks. Operators and engineers will also need tools to efficiently manage switches from onsite and remote control room locations. Whether for initial installation, configuration backups, firmware updates, or configuration rollbacks, an efficient solution to accomplish these tasks will mean a faster time to market and improved system uptime.

During initial installation at onsite locations, manual switch configuration can be a daunting task for large-scale networks. Aside from labour costs during initial configuration, possible input errors resulting from manual configuration will require additional time to diagnose and troubleshoot. A mass-configuration utility is a must to allow maintenance engineers to minimise the time required to configure network switches. Some network configuration tools now support smart configuration methods to enable network link sequence detection to eliminate the possibility of manual input errors to reduce total cost of ownership.

Without effective network management software for remote switch management, industrial operators are unable to monitor, identify, and react to network issues immediately, which can result in production losses and safety concerns. Typical enterprise network management software, which use complex features and sophisticated user interfaces will have a high learning curve and is unsuitable for use in industrial environments. An effective industrial network management software tool can auto-detect network devices and offer a virtual physical network topology to allow operators to visually monitor, manage, and diagnose network devices and events in real time.

Legacy devices, PLCs, and scadas are still widely used in field-level applications. In order to effectively converge and manage these existing devices, switches should be enabled with industrial Ethernet protocols, such as Modbus TCP, Profinet, and EtherNet/IP to offer operators the efficiency of centralised network management with greater network scalability and flexibility. To optimise system performance and improve network manageability, switches should integrate seamlessly with industrial automation networks for centralised scada control and monitoring.

Conclusion: industrial networks require future-proof switches

To future-proof large-scale industrial Ethernet networks, industrial operators must seriously consider the key requirements of industrial Ethernet switches, along with industrial network manageability and maintainability.

Industrial switches must be able to resist high level electro-magnetic disturbances, severe shock and vibration, and extreme high temperatures. For scalability and aggregation requirements, especially in high-definition video applications, industrial switches will need to have multiple gigabit-speed ports. Network redundancy for industrial Ethernet switches should still be able to recover network connectivity in millisecond timeframes, even when hundreds of switches are on the network. Switch security must not be overlooked, access authentication (IEEE 802.1X, RADIUS, or TACACS+) and secure data transmissions (SNMPv3, HTTPS, SSH) are both critical factors to consider to establish role-based account management. Lastly, how quickly and efficiently industrial operators are able to respond to resolve network abnormalities to minimise system downtime will ultimately have a direct impact on total cost of ownership.

For more information contact RJ Connect, +27 (0)11 781 0777, [email protected], www.rjconnect.co.za



Credit(s)



Share this article:
Share via emailShare via LinkedInPrint this page

Further reading:

EtherCAT interoperability removes industrial networking barriers
Fieldbus & Industrial Networking
Selecting the right communication technology is one of the most important decisions engineers make, and interoperability helps with that decision. Key development tools and standards ensure interoperability among many EtherCAT devices and manufacturers.

Read more...
Condition monitoring to go
Turck Banner Southern Africa Fieldbus & Industrial Networking
Anyone who wants to efficiently monitor the climate in control cabinets will find a comprehensive range of control cabinet monitors for the DIN rail in Turck Banner’s cabinet condition monitoring family.

Read more...
Affordable building management system product range
Fieldbus & Industrial Networking
Schneider Electric has unveiled its EasyLogic Building Management System range, designed for basic building architectures, to the local marketplace. This is a complete and cost-effective range of field controllers and sensors that are both easy to install and scalable.

Read more...
Flexible EtherCAT communication interface for DALI-2
Beckhoff Automation Fieldbus & Industrial Networking
The EL6821 EtherCAT Terminal from Beckhoff allows up to 64 DALI/DALI-2 slaves and 64 DALI-2 input devices to be connected. The TwinCAT 3 System Manager makes it easy to configure and parameterise DALI devices flexibly.

Read more...
EtherCAT-based control technology for building automation
Beckhoff Automation Fieldbus & Industrial Networking
Modern non-residential buildings place many high demands on building automation. This can be optimally implemented with EtherCAT-based control technology from Beckhoff, which provides an efficient central automation architecture thanks to ultra-fast data communication.

Read more...
PC-based control for university studies
Beckhoff Automation Fieldbus & Industrial Networking
The IDEA box developed at Heilbronn University of Applied Sciences is designed to introduce students to the topic of Industry 4.0 in a simple and practical way. At the core of the corresponding demo case is PC-based control from Beckhoff.

Read more...
Boosting cybersecurity in substation automation systems
RJ Connect Electrical Power & Protection
A significant surge in distributed energy resources (DERs) and energy storage systems, along with the upward trend in unmanned substations, have made power grids a lot more complex. To address these instabilities in power grids, digital substations increasingly play an important role in power transmission.

Read more...
A new standard in high-speed Ethernet communication
Fieldbus & Industrial Networking
The TXMC897 module from TEWS Technologies supports a range of Ethernet standards and speeds, making it suitable for diverse applications, including the defence, industrial, and IIoT markets.

Read more...
Safeguarding an energy storage system for renewable energy
RJ Connect Electrical Power & Protection
Following the trend toward decarbonising the global economy, a grid-level energy storage system (ESS) builder is expanding its ESS capacity for renewable energy. Its mission is to provide a reliable and affordable ESS, as this is key for grid operators to be able to balance power demand and supply during peak and off-peak times.

Read more...
Data-driven battery production
Turck Banner Southern Africa Fieldbus & Industrial Networking
The availability of high-performance batteries at moderate prices is one of the most important factors for the success of electromobility. As a long-standing automation partner to the automotive industry, Turck Banner supports the major battery manufacturers with its know-how.

Read more...