Temperature Measurement


Intrinsically safe

February 2009 Temperature Measurement

After time, temperature is the second most measured physical unit in production. Temperature is an important indicator of product quality, safety and equipment conditions.

Infrared thermometers in industry

During the last five years the IR sensor market has seen two major trends. Firstly, IR thermometers are significantly lower in cost. The most expensive parts of an infrared thermometer are the lenses and detectors. New lens materials and technologies and mass production of IR detectors for consumer products such as toasters, hair dryers and ear-thermometers, have resulted in lower prices for these two important components.

Secondly, IR sensors are becoming smaller in size. In the past, the measurement of low temperatures made it necessary to use fast (low F number) lenses with relatively large diameters in order to capture enough emitted energy. Progress in detector technology and the use of micro system techniques together with improved preamplifier designs have helped reduce the dimensions of the IR-sensing head dramatically. Because the newer sensors have better response characteristics they require less energy to achieve a usable signal, resulting in smaller lens diameters.

Detector and optics

There are two main groups of detectors found in IR thermometers – thermal and photoelectric or photon detectors.

Thermal detectors change their own temperature in response to heat radiated from the process under measurement. Similar to a thermocouple, this produces a corresponding voltage fluctuation proportional to the change in temperature.

Photoelectric detectors (eg, photo diodes) react to the level of photon bombardment which causes a variation in the current flowing through the device.

Thermal detectors respond less quickly than the photoelectric detectors because they have to feel a temperature change. In the case of thermal detectors slow means time constants in the millisecond range compared to nano or microseconds for photoelectric detectors.

Choosing the correct IR unit

Selecting a device with the correct operating wavelength for the temperature under measurement has a significant influence on the accuracy of the results. It is best to use the shortest possible wavelength and Figure 1 indicates the common wavelengths used with respect to target temperature and error. From this it can be see that to measure above 900°C users should not use the common 8-14 micron types, but should rather opt for a 1 or 2 micron wavelength.

Figure 1
Figure 1

Trends in electronic design

Due to the increasing expectations of users and competition among manufacturers, infrared thermometers are continually being improved and electronic design is an area that has seen the most improvements recently.

Process industries continue to need sensors with higher accuracy and repeatability as they look for ways to cut costs, maximise their production lines and monitor quality. Easy installation, use and maintenance continue to be important, as does the ability to withstand harsh environmental conditions. Field checking and field calibration features are becoming more and more important as companies look to optimise their personnel and equipment resources. Manufacturers need IR sensors with a wide operating temperature range that cover more applications and eliminate the need for cooled housings, to keep the costs down.

Manufacturers are taking advantage of the many developments in other industries to continue to expand the capabilities and efficiencies of the IR thermometer. These advances have made a variety of products readily available and affordable where previously they were only used for specific military applications because of the associated cost.

Advances in the cost/performance ratio of detectors and optics are helping expand the applications where IR can be used effectively and yield a better return on investment. Two colour or ratio measurement and units with built in visual cameras are some of the most recent advances.



Credit(s)



Share this article:
Share via emailShare via LinkedInPrint this page

Further reading:

High-precision data loggers for wire and thermocouple probes
Senseca Temperature Measurement
Senseca, formerly the GHM Group, has launched new handheld meter/data loggers for Pt100 four-wire probes and thermocouple probes. These are redesigned with enhanced features.

Read more...
How wet steam undermines boiler efficiency
Endress+Hauser South Africa Temperature Measurement
Endress+Hauser understands the daily challenges and demands placed on energy and utility managers across the spectrum of steam generation, distribution and consumption activities. Its global team is committed to working with its partners to overcome these complexities, and particularly those that aim for a safe, economic and sustainable sitsce of steam energy production and delivery.

Read more...
Dramatically reducing greenhouse emissions
Temperature Measurement
Online teaser: There is considerable potential for reducing CO2 emissions in the mill process by optimising the heat source for drying. The most promising approach to achieving a carbon neutral process in a hot gas generator is the combustion of green hydrogen.

Read more...
Infrared camera for condition monitoring and early fire detection
Instrotech Temperature Measurement
The Optris PI 640i thermal imager is the smallest measuring VGA infrared camera, with a body-sized volume of 45 x 56 x 90 mm, and weighing only 269 to 340 g, depending on the lens. It counts among the most compact thermal imaging cameras on the market.

Read more...
Paint curing applications in the automotive industry
R&C Instrumentation Temperature Measurement
For successful paint cure, irrespective of the paint chemistry being used, there is a critical need to measure and control the temperature of the car body as it travels through the oven. Today, paint ovens are controlled in a sophisticated fashion via thermocouples located in each zone to give constant feedback on the ambient temperature.

Read more...
Universal temperature transmitter with drift detection
WIKA Instruments Temperature Measurement
The new model T38 digital temperature transmitter from WIKA enables extremely flexible and stable temperature measurement. The instrument offers a maximum of sensor connection combinations, and a new type of drift detection.

Read more...
Temperature monitoring in the metal casting process
Instrotech Temperature Measurement
During metal casting, the liquid material is poured into a mould, and after solidification becomes a solid body. Both too-high and too-low casting temperatures can lead to quality defects. The compact Optris PI 05M infrared thermal imaging camera from Instrotech can monitor the casting process.

Read more...
Pyrometer range with enhanced features
Temperature Measurement
AMETEK Land has relaunched its market-leading SPOT pyrometer range with enhanced features and benefits for a wide range of industrial applications. The new SPOT+ family offers a wide range of temperature measurement from 50 to 3500°C, and a choice of different wavelengths for applications including metals, glass, cement and lime kilns, and foundries.

Read more...
Versatile thermal imaging camera
Vepac Electronics Temperature Measurement
The PeakTech 5610 B is a versatile thermal imaging camera with a range of -20 to 400°C, and a thermal resolution of 220x160 thermal pixels, which makes temperature differences easily recognisable for every user.

Read more...
Infrared measurement technology for scrap recycling
Instrotech Temperature Measurement
Instrotech offers fire protection with infrared cameras and IR measurement technology. One application is a shredding facility in a scrap recycling plant that operates unmanned for an extended period and has known risks for starting a fire.

Read more...