Is your building safe from fire?

March 2019 IS & Ex

Fire safety in high occupancy buildings is critical. Large numbers of people produce greater activity within these environments, which can lead to things going wrong. In particular, fire can escalate quickly into a catastrophe. This eventuality needs to be confronted in the design and protection of buildings and their occupants.

Smoke inhalation too can be fatal. Smoke visually obscures escape routes that can prevent fast and safe evacuation. It also inhibits the performance of fire rescue responders. These are just some of the dangers surrounding fire within high occupancy buildings that place hard emphasis on early detection of fires and alerting occupants to the threat.

Fire sensing methods

The traditional method of sensing fire is to detect smoke by means of light obscuration within a sensing chamber. This is known as optical smoke sensing. However, there are challenges to sensing fires within bedrooms in high occupancy buildings using such methods. This is because of the human activity that occurs within these areas. Often bedroom applications result in unwanted fire alarms with many people believing that the smoke detector is ‘too sensitive’.

This is not the case. Spraying of aerosols such as deodorants, hair sprays or air fresheners mimic the obscuration caused by smoke. Similarly steam from showers can also do this. The key is to separate these unwanted phenomena from a genuine fire, while providing an early and stable alarm signal.

Alien Systems & Technologies utilises Protec 6000PLUS detectors that can discriminate between aerosols, steam and genuine smoke by utilising multi-sensor technology governed by an algorithm that makes the fire alarm decision. These detectors must have all three fire phenomena present – smoke, a rise in temperature and a rise in carbon monoxide.

Testing shows that even with hot steam or aerosols, the problem of unwanted alarms is solved. For example, in one such test steam was allowed to fill a Perspex test chamber with three detectors present: an optical detector, an optical/heat detector and an optical/heat/CO detector. The steam filled the test chamber and after approximately 35 seconds the optical detector produced a fire alarm. The test was allowed to run for a period of 5 minutes and the other two detectors ignored the steam and did not produce any fire alarms.

In a following test, steam was used to fill the Perspex chamber and after approximately 40 seconds the optical detector produced a fire alarm. Then after one minute a small smouldering piece of towel is placed within a test chamber with the steam still present to simulate a small fabric fire that is common in a bedroom. After another minute, the optical/heat/CO detector produced a fire alarm because it sensed a genuine fire was present. This is because it sensed the obscuration of light, a rise in temperature and a relatively high amount of carbon monoxide and the algorithm monitoring the sensor was able to make an accurate decision that a genuine fire was present. The optical/heat detector produced a fire alarm one minute afterwards.

Correct selection of detectors is vital

These tests show that the selection of fire alarm detectors in buildings is vital to prevent unnecessary evacuations from erroneous fire alarms. The disruption to occupants as well as the fire brigade is severe. Such unwanted alarms can lead to apathy, which then further increases the risk.

AST’s Protec 6000PLUS detectors avoid this scenario as only genuine fires are sensed, and sensed early. There are also enhancements that can be added to the detector range. These include the option to add a visual alarm to the detector body. Programmable speech messages can also be added over and above standard audible tones. This allows for clear fire alarm evacuation commands to be broadcast without the need for extra annunciators. Furthermore, other non-fire emergency messages can also be broadcast over the fire alarm system. For hotels, AST can even integrate a vibrating pillow into the fire alarm system in order to provide an alarm signal that will alert sleeping occupants and inform them to follow the escape route.

For more information contact Alien Systems & Technologies, +27 11 949 1157, sales@astafrica.com, www.astafrica.com



Credit(s)



Share this article:
Share via emailShare via LinkedInPrint this page

Further reading:

The importance of up-to-date alarm annunciators
January 2020, Omniflex Remote Monitoring Specialists , IS & Ex
At 1.23 pm on Sunday, 24 July 1994, twenty-six people were injured when an explosion erupted through an oil refinery in an otherwise quiet corner of South Wales in the United Kingdom. The site was occupied ...

Read more...
Gas detector for multiple applications
January 2020, Comtest , IS & Ex
Comtest, the local representative of Industrial Scientific, global leader in gas detection, has announced a new version of the Ventis Slide-on Pump. The new pump is compatible with both Ventis MX4 and ...

Read more...
Light grid with integrated muting unit
November 2019, ifm - South Africa , IS & Ex
The new generation of light grids from ifm electronic allow for the muting mode without an external junction box or a muting relay being required, as they are already integrated into the receiving element. ...

Read more...
Light grid with integrated muting
October 2019, ifm - South Africa , IS & Ex
The new generation of light grids from ifm electronic incorporates muting mode without an external junction box or a muting relay being required, as they are already integrated into the receiving element. ...

Read more...
How integrated visual management and remote monitoring demystify machine safety
September 2019, Turck Banner , IS & Ex
This article shares common challenges for machine safety, and shows how combining easy-to-use safety devices with visual indication and remote monitoring capabilities can help make safety simpler and more effective.

Read more...
Security concerns for safety systems
September 2019, Phoenix Contact , IS & Ex
A common strategy required for the future.

Read more...
Taking safety to the next level
September 2019, SICK Automation Southern Africa , IS & Ex
SICK Automation is a world leading manufacturer of sensors, safety systems and automatic identification products. The next step for safety – this core idea therefore underpins the entire design of the ...

Read more...
Alarm system upgrade from Omniflex
September 2019, Omniflex Remote Monitoring Specialists , IS & Ex
Fiddler’s Ferry Power Station was constructed by the CEGB (Central Electricity Generating Board) in the UK and came into full operation in 1973. It has four 500 MW sets, giving a total generating capacity ...

Read more...
Intrinsic safety barcode scanning from Extech Safety Systems
September 2019, Extech Safety Systems , IS & Ex
Extech Safety Systems has worked with UK-based Mobexx to develop the MobXscan mobile application for barcode scanning with mobile devices. The app has been released for Windows 10 and Android, offering ...

Read more...
Smart devices for Ex areas
September 2019, Pepperl+Fuchs , IS & Ex
The Pepperl+Fuchs brand ecom has launched its next generation ATEX Zone 1/21 and Div. 1 certified, intrinsically safe 4G/LTE-Android smartphone – Smart-Ex. The Smart-Ex 02 is a complete new development ...

Read more...