For this article, I would like to report on the ongoing work and direction of the Next Generation Base-T Study Group in IEEE 802.3. What is driving the development of the next generation of Ethernet Standard over twisted pair copper cabling? Answer, the need for higher speed switch-to-server connections.

Recent trends indicate that a large majority of these network connections will be at 10 Gbps by 2015 and will be migrating to 40 Gbps starting in 2015. The NGBase-T study group is currently focusing on defining the topology, the reach objectives, the cabling requirements and the power consumption of the next generation physical layer interface (PHY).

Let us start by looking at the evolution of the 10GBase-T standard published almost six years ago. Today, 10GBase-T represents about 25% of the switch-to-server market. The main factors that slowed the adoption in the market were the relatively high cost and power consumption of the PHYs compared to 1000Base-T. The first generation 10G Base-T PHYs consumed about 12 watts of power.

Current generation 10GBase-T PHYs, using today’s chip technology, consume considerably less power, between 1,5 to 4 watts depending on the length of the channel. They also take up less space and are more economical. All these advancements are leading to an accelerated deployment of 10GBase-T in the data centre, particularly with the introduction of LAN-on-motherboard (LoM) chips in 2012.

Having learned the lesson from the evolution of 10GBase-T technology, low power consumption is one of the most important considerations for the next generation 40GBase-T PHY. A contribution by Will Bliss of Broadcom is illuminating in this respect. Entitled ‘A Simple Model of Relative Power vs. Reach,’ it shows that the relative power consumption for 40 Gb/s with respect to 10GBase-T is about the same for a reach of 22 metres, about two times more for a reach of 34 metres and four times more for a reach of 46 metres. Every 12 metre increase in reach approximately doubles the power consumption.

In another presentation, Scott Kipp, also of Broadcom, noted that the power consumption can be related to the product of length times the bandwidth. For example, the power consumption of 10G at 100 metres is roughly the same as 40G at 25 metres. The relative power consumption for 40G at 20 metres is approximately 0,8. The relative power consumption for 40G at 10 metres is approximately 0,4. Shorter distances result in considerably less power consumption. The same presentation by Kipp showed that for an ‘end of row topology’ a switch rack at the end of a row can support up to three server racks for a cable distance of 10 metres and 18 server racks for a cable distance of 20 metres. Using a server density of 40 servers/rack, 18 server racks can accommodate 720 servers.

For a ‘middle of row’ topology, with the switch rack located in the middle of a row, a switch rack can support up to 36 server racks or 1440 servers. When a ‘middle of row’ switch rack also supports servers in adjacent aisles, 25 additional racks in each adjacent aisle can be accommodated, for a total of 50 server racks, or 1000 additional servers when using a server density of 40 servers/rack. All this means that with a suitable data centre topology, thousands of high density, rack mounted servers can be supported with a 20 metre link to a modular switch.

Another important consideration in the development of the next-generation Base-T Ethernet standard is the ability to interoperate with legacy slower-speed Ethernet technologies through the function of auto-negotiation.

Compatibility, for auto-negotiation, is facilitated by the use of the 8-pin modular (RJ-45) connector that is currently defined for lower speed Ethernet applications. TIA 42.7 subcommittee is currently developing a Category 8 cabling standard that includes the 8-pin modular connector and 4-pair balanced twisted pair cable that are specified to 2 GHz, which is four times the bandwidth for existing Category 6A cabling.

There was also a joint presentation from Belden, CommScope, Intertek and Fluke Networks that demonstrated the technical feasibility of a cabling system using prototype, Category 8, RJ-45 connectors and prototype Category 8 balanced twisted-pair cables from two different vendors for a short reach (5 m) and long reach (40 m) permanent link configuration. The testing was performed at Intertek, an independent third-party test laboratory, and showed that it is feasible to make components that meet the proposed requirements in the draft Category 8 standard.

What is the main take away from this meeting? After consideration of all the discussion and associated contributions on topology, power consumption and reach, the NGBase-T Study group agreed to the following motions with greater than 75% support, 1) to focus on presentations regarding reach objective in the range of 20 metres to 30 metres, 2) to adopt a 2-connector channel model as an objective.

The above column originally appeared in Cabling Networking Systems, a magazine based in Toronto, Canada. The information presented is the author’s view and is not official TIA correspondence.

For more information contact Greg Pokroy, Jaycor International, +27 (0)21 447 4247, [email protected], www.jaycor.co.za





Share this article:
Share via emailShare via LinkedInPrint this page

Further reading:

Cables and wires for food and beverage
LAPP Southern Africa Enclosures, Cabling & Connectors
The strict hygiene regulations for handling foodstuffs stipulate particularly complex requirements for electrical components. The cables and accessories used must withstand a wide range of chemical, thermal and mechanical loads, and also function perfectly at all times in refrigerated and damp rooms.

Read more...
Cable protection for longer runs
igus Enclosures, Cabling & Connectors
Polymer energy chain manufacturer, igus has introduced a new lighter weight e-chain for cable management and protection applications with large unsupported lengths and high fill weights. This was previously the domain of larger, more expensive energy chains.

Read more...
Robust Ethernet cordset series of cables
Turck Banner Southern Africa Enclosures, Cabling & Connectors
Turck Banner offers a product range comprising a wealth of different connectors and cables, including over 115 000 connection technology solutions with differing degrees of complexity.

Read more...
Panel building should be streamlined
Schneider Electric South Africa Enclosures, Cabling & Connectors
Data centres run critical applications, and require equipment and infrastructure that operate at 100% uptime, as any downtime due to faulty components could have catastrophic ramifications.

Read more...
Robust Ethernet series of cables and connectors for industrial protection
Turck Banner Southern Africa Enclosures, Cabling & Connectors
Turck Banner offers a product range comprising a wealth of different connectors and cables, including over 115 000 connection technology solutions with differing degrees of complexity.

Read more...
UV-resistant enclosures
Communica Enclosures, Cabling & Connectors
Hammond Manufacturing has a range of glass-reinforced polyester (GRP) enclosures which are lightweight, corrosion resistant, and also UV-resistant.

Read more...
Secure fastening in high-vibration applications
Bearing Man Group t/a BMG Enclosures, Cabling & Connectors
Vibration and shock can quickly impair joint integrity, and negatively affect overall product performance, especially in demanding applications in sugar mills like vibrating screens. BMG’s Lock Bolt pins and collars, which are designed to replace bolted and welded joints, provide high strength, vibration-resistant fastening that reduces downtime and improves safety standards by removing sheet gap and maintaining tension over time.

Read more...
Ready made cables are revolutionising drive applications
Enclosures, Cabling & Connectors
Innovative manufacturer of motion plastics, igus, has emerged as a trailblazer in the world of drive applications, with the introduction of a full range of ready to use cabling solutions to fit all commonly used drive systems.

Read more...
Powering the Perforex machine
Rittal Enclosures, Cabling & Connectors
Following its acquisition of a Perforex machine, Rittal South Africa has partnered with Rubicon Group to secure a backup power solution that will ensure the machine’s uninterrupted operation.

Read more...
Ultra-rugged connectors enhance IIoT connectivity
Spectrum Concepts Enclosures, Cabling & Connectors
Fischer Connectors has released ultra-robust Single Pair Ethernet (SPE) and USB 3.2 Gen 2 connectivity solutions to meet the specific requirements of IIoT applications in rugged environments.

Read more...